The Tech Support crew here at Kele frequently gets quizzed by customers who have a voltage-output signal source which must drive multiple voltage-input loads. Requests for “voltage signal replicators” come in frequently. Sometimes extra hardware is needed, but sometimes it isn’t! So we thought it might be a good idea to write an article addressing […]
Read PostCategory: Technical Reference
47 Ways to Wire Your Power Meter Wrong
Some of you might remember that back in 1975 Paul Simon had a hit song entitled “50 Ways to Leave Your Lover.” Well, coming in a close second are the number of ways (47) that you can wire a 3-phase power meter incorrectly! In this article we’ll briefly discuss why there are so many ways […]
Read PostHot and Steamy Pig Tails! How to Measure the Pressure of Steam Without Breaking Your Pressure Transmitter
So, in checking the specs, the PTX1-06, can read pressure up to 200 degrees Fahrenheit, like most pressure transmitters in the marketplace. But, steam is steam at 212 degrees Fahrenheit. How’s that going to work? This little piggy says to put a copper extender on a pig tail, and shoot the steam to the side […]
Read PostTemperature Sensor Curve ID Numbers
Need help figuring out what type sensor you need for your automation system? This handy temperature curve chart might help. If not, give Kele a call! Sensor Type Temperature Sensor Description Typical Sensor User 3 10,000Ω @ 77°F, Type III material AET, American Automatrix, Andover, Carrier, Delta, Invensys, Teletrol, York 21 2252Ω @ […]
Read PostTime Delay Relay Functions Explained
Understanding the differences between various time delay relay operations such as On-Delay or Interval can be a bit confusing. These simple diagrams may make it easier to visualize what’s happening during the timer operation(s). At Kele, our goal is to make product selection and usage as easy as […]
Read PostExtend Your Reach with the ST-A Series by Precon
Kele’s Precon brand has a sensor solution for ALL your application needs, even the odd ones! Job site situation #1: You need a temperature sensor for your tank or cooling tower sump, but they don’t make one long enough. Special ordering one seems daunting. What if it doesn’t work out and you can’t send it back? […]
Read PostGreen Buildings need Clean Electrical Power for Sustainability
Major changes are taking place in the United States as we all move forward to reduced energy consumption and utilization of renewable energy sources in our homes, offices, campus environments, and factories. As new technology becomes available with ever increasing returns on investment many owners are ready to become part of the “Green Movement” that […]
Read PostTHE (RS-485 Network) TERMINATOR Or The Dance of the Data Pulses
If you’re involved with building automation systems you know (unless you’ve been living under a rock like the guy in that insurance commercial) that the modern trend is to connect all your building controls together on networks. Networks make it easy to add or move control nodes as your building control needs change since the […]
Read PostWhat Are Power System VARs?
Most people involved in building automation are familiar with kW, which is the rate at which a building is consuming energy from the power company. But there is another power system parameter known as VAR/kVAR which is less well understood. In this article we will attempt to dispel some of the VAR mystery. The term […]
Read PostAC to DC – Linear Versus Switch-Mode Power Supplies
For years, Kele has provided dependable, quality 24 VDC power supplies like the DCP-1.5-W, DCPA-1.2, DCP-250, PW2, and the SLS Series. All of these DC power supplies are “linear” power supplies. Another type of DC power supply gaining popularity with building automation and temperature control contractors is called a “switch-mode” power supply (PS6R Series). While both […]