340BN/MB-00 | Badger Meter | Flow
BTU XMITTER W/ BACNET OUTPUT
Brand:Badger Meter
MPN:340BN/MB-00
SKU:340BN/MB-00
List Price:
$2,133.00
Today's Price:
$1,109.16
Log in for customized pricingproduct specifications
Communication Protocol
BACnet
Type
BTU Meter
Supply Voltage (Nominal)
24 VAC,24 VDC
Max Temperature
158 °F
product series specifications
Supply Voltage: 12-35 VAC ±5% or 12-24 VDC ±10%
Supply Current: 60 mA @ 12 VDC
Input Signal:
All flow sensors: Excitation voltage 3-wire, 7.9-11.4 VDC, 270Ω source impedance Pulse sensors: Signal amplitude 2.5 VDC threshold, signal limit <35V AC or DC peak, frequency 0-10 kHz, pull-up 8.5 VDC @ 2kΩ source impedance
Sine wave sensors: Signal amplitude 10 mV p-p threshold, signal limit <35V AC or DC peak, frequency 0-10 kHz Temperature sensors: Two matched 10 kΩ @ 25°C, two-wire, type II
Output Signal:
Output Pulse, isolated solid-state switch programmed for units of energy or flow
BN Output BACnet and Modbus communication
LW Output LonWorks communication
N2 Output N2 communication
Pulse Output:
Voltage range: 0 to ±60V (DC or AC peak)
On-state load current: 700 mA maximum
On-state load resistance: 700 mΩ
Off-state leakage: < 1µA @ 60 V peak
Pulse width: adjustable from .05 to 5.0 seconds
User Interface:
Computer connection allows visibility of real-time flow rate, flow total, temperature readings, energy rate and energy total
Communication: BACnet and Modbus, LonWorks, Metasys N2, or Modbus
Configuration: Windows® based A301-20 programming kit (order separately) cable connects to DIC communication port and DB9 COM port on a computer for calibration of flow sensor information, units, output scaling; unit must be powered to configure
Mounting:
-00 Enclosure Surface mount, no enclosure
-02 Enclosure Surface mount, in metal enclosure
-03 Enclosure Surface mount, in plastic enclosure
-04 Enclosure DIN rail mount, with clips
Operating Temperature: -20° to 158°F (-29° to 70°C)
Weight: 0.3 lb (0.14 kg) without enclosure
Warranty: 1 year
product series features
- AC or DC powered for installation flexibility
- Field programmable makes changes easy
- Small footprint saves space
- Uses two matched 10 Kilo-Ohms Type II thermistors
- Used with Data Industrial flow sensors
- Bas communication standard
more information & related documents
Series Description
The Badger Meter 340 Series is an inexpensive BTU transmitter that calculates energy usage based on liquid flow rate from a Data Industrial impeller flow sensor, Type II and differential temperature using two 10 k Ohm thermistor inputs. The onboard microcontroller provide precise measurements accurate drift-free outputs. Configuration is accomplished with a separately purchased Windows® based software programming kit. The 340 Series comes with onboard communication technology for LonWorks, BACnet, Johnson Controls N2 Metasys, or Modbus networks.
Kele Description
BTU XMITTER W/ BACNET/ MODBUS OUTPUT, TRANSMITTER ONLY
Manufacturer