340BN/MB-00 | Badger Meter | Flow

BTU XMITTER W/ BACNET OUTPUT

Brand:Badger Meter

MPN:340BN/MB-00

SKU:340BN/MB-00

List Price:

$2,133.00

Today's Price:

$1,109.16

Lead time of 14 days. Chat with Kele experts now

product specifications

Communication Protocol

BACnet

Type

BTU Meter

Supply Voltage (Nominal)

24 VAC,24 VDC

Max Temperature

158 °F

product series specifications

Supply Voltage: 12-35 VAC ±5% or 12-24 VDC ±10%

Supply Current: 60 mA @ 12 VDC

Input Signal:

All flow sensors: Excitation voltage 3-wire, 7.9-11.4 VDC, 270Ω source impedance Pulse sensors: Signal amplitude 2.5 VDC threshold, signal limit <35V AC or DC peak, frequency 0-10 kHz, pull-up 8.5 VDC @ 2kΩ source impedance

Sine wave sensors: Signal amplitude 10 mV p-p threshold, signal limit <35V AC or DC peak, frequency 0-10 kHz Temperature sensors: Two matched 10 kΩ @ 25°C, two-wire, type II

Output Signal:

Output Pulse, isolated solid-state switch programmed for units of energy or flow

BN Output BACnet and Modbus communication

LW Output LonWorks communication

N2 Output N2 communication

Pulse Output:

Voltage range: 0 to ±60V (DC or AC peak)

On-state load current: 700 mA maximum

On-state load resistance: 700 mΩ

Off-state leakage: < 1µA @ 60 V peak

Pulse width: adjustable from .05 to 5.0 seconds

User Interface:

Computer connection allows visibility of real-time flow rate, flow total, temperature readings, energy rate and energy total

Communication: BACnet and Modbus, LonWorks, Metasys N2, or Modbus

Configuration: Windows® based A301-20 programming kit (order separately) cable connects to DIC communication port and DB9 COM port on a computer for calibration of flow sensor information, units, output scaling; unit must be powered to configure

Mounting:

-00 Enclosure Surface mount, no enclosure

-02 Enclosure Surface mount, in metal enclosure

-03 Enclosure Surface mount, in plastic enclosure

-04 Enclosure DIN rail mount, with clips

Operating Temperature: -20° to 158°F (-29° to 70°C)

Weight: 0.3 lb (0.14 kg) without enclosure

Warranty: 1 year

product series features

  • AC or DC powered for installation flexibility
  • Field programmable makes changes easy
  • Small footprint saves space
  • Uses two matched 10 Kilo-Ohms Type II thermistors
  • Used with Data Industrial flow sensors
  • Bas communication standard

more information & related documents

Series Description

The Badger Meter 340 Series is an inexpensive BTU transmitter that calculates energy usage based on liquid flow rate from a Data Industrial impeller flow sensor, Type II and differential temperature using two 10 k Ohm thermistor inputs. The onboard microcontroller provide precise measurements accurate drift-free outputs. Configuration is accomplished with a separately purchased Windows® based software programming kit. The 340 Series comes with onboard communication technology for LonWorks, BACnet, Johnson Controls N2 Metasys, or Modbus networks.

Kele Description

BTU XMITTER W/ BACNET/ MODBUS OUTPUT, TRANSMITTER ONLY

Manufacturer