Transducers

UAT-1, UAT-2 Series



Product Bar End
Product Bar End

UAT-1, UAT-2 Series

Universal Analog Transducers UAT-1, UAT-2 Series

Universal Analog Transducers

 

The UAT-1 and UAT-2 Series universal analog transducers are used for analog signal conversion or to scale signal. The analog signal converter will accept a DC voltage, current, or resistive input signal and output a non-isolated voltage or current output. These transducers can be direct or reverse acting and are easily field calibrated to meet a wide variety of applications in building automation systems, BAS. The UAT-1 is furnished in a unique slim-line design housing, which saves panel space, and can be ordered with an optional DIN rail mounting adapter. The UAT-2 is a snap-track mounted version and operates the same as the UAT-1.


Products
Filter:

(Wholesale customers, log in for your special pricing)

QtyModelDescriptionIn StockList PriceInternet Price
UAT-1-47 UNIVERSAL ANALOG TRANSDUCER, ENCLOSURE, DIN RAILIn Stock174.0097.44
UAT-1-C-47 UNIVERSAL ANALOG TRANSDUCER - ENCLOSURE, DIN-RAILIn Stock217.00121.52
UAT-1C UNIV ANALOG XDUCR-ENCL-CALIBRIn Stock215.00120.40
UAT-2C UNIV ANALG XDUCR-TR MTD-CALIIn Stock164.0091.84

Accessories

No accessories found
Features
  • DC voltage, current, or resistive input
  • Inputs from 0-20 VDC, 0-40 mA or 0-10 kΩ
  • Input and output jumper selectable and easily field calibrated
  • Outputs from 0-18 VDC or 0-20 mA
  • Direct or reverse acting, jumper selectable
  • Reference voltage and current available to power an input device or sensor
Specifications

Supply Voltage:24 VAC ±10%, half-wave; or 24 VDC ±10%

Supply Current:50 mA maximum @ 24 VDC; 100 mA maximum @ 24 VAC

Input:Jumper selectable and adjustable; Voltage ranges from 0-1.09 VDC (w/minimum span 55 mV) to 0-20 VDC (w/minimum span 1V); Current ranges from 0-4 mA (minimum span 0.2 mA) to 0-40 mA (minimum span 2.2 mA); Three-wire potentiometer ranges from 0-100Ω to 0-10 kΩ; Two-wire variable resistance ranges from 0-100Ω to 0-5 kΩ

Input Signal:DC voltage, current, or resistance

Input Impedance:250kΩ @ 0-4 mA & 0-40 mA; 156kΩ @ 0-1.09 VDC & 0-10.9 VDC; 293kΩ @ 0-2 VDC & 0-20 VDC

Action:Direct or reverse acting

Linearity:<0.1% of span

Output:Jumper selectable and fully adjustable zero/span

Voltage:0-18 VDC @ > 900Ω

 :0-10 VDC @ > 500Ω

Current:0-20 mA @ < 650Ω

Output Current:For sensor excitation only, jumper selectable; 1.2 mA @ 5 kΩ maximum, 5 mA @ 1.5 kΩ maximum, 10 mA @ 750Ω maximum

Output Voltage:For sensor excitation only, jumper selectable; 1.2 VDC @ 12 mA maximum (100Ω minimum), 5 VDC @ 12 mA maximum (417Ω minimum), 10 VDC @ 12 mA maximum (834Ω minimum)

Wiring Terminations:Screw terminals

Operating Temperature:32° to 158℉ (0° to 70℃)

Operating Humidity:5% to 95% RH (non-condensing)

Dimensions:

 :UAT-1 3.0″H x 4.8″W x 1.5″D (8.6 x 5.1 x 12.4 cm)

 :UAT-2 3.3"H x 4.6"W x 1.0" D (8.3 x 11.8 x 2.5 cm)

Weight:0.8 lb (0.36 kg)

Warranty:1 year