Tools and Test Equipment

AQ Series



Product Bar End
Product Bar End

AQ Series

Portable Indoor Air Quality Monitors AQ Series

Portable Indoor Air Quality Monitors

 

The E Instruments AQ Comfort indoor air quality monitor is the latest and most innovative all-in-one instrument for basic IAQ analysis. The AQ Comfort can be configured for up to 4 different parameters alone or all together including CO2, CO, temperature, and %RH. The AQ VOC monitor provides air quality testing professionals the flexibility of testing a wide range of VOC's in one handheld unit.


Products

(Wholesale customers, log in for your special pricing)

QtyModelDescriptionIn StockList PriceInternet Price
AAA32-240 UPGRADE TO ADD O2 SENSOR (0-21 %) TO AQ KITINFO453.00226.50
AACKP01 DIFFERENTIAL PRESSURE KIT (FOR AQ MODELS)INFO123.0061.50
AQ CO-200 UPGRADE TO ADD CO SENSOR (0-200 PPM) TO AQ KITINFO910.00455.00
AQ COMFORT-2 AIR QUALITY TESTER, CO2, TEMP, UPGRDE TO HUM. & COINFO2,485.001,242.50
AQ COMFORT-3 AIR QUALITY TESTER, CO2, CO, TEMP, HUM., WB, DPINFO3,675.001,837.50
AQ COMFORT-4 AIR QUALITY TESTER, CO2/TEMP/HUM/WB/DP/UPGRD TO COINFO4,989.002,494.50
AQ EXPERT-1 AIR QUALITY TESTER, CO2/TEMP/HUM/WB/DP/BP/DT/ADD6INFO9,239.004,619.50
AQ FMH UPGRADE TO ADD CH2O SENSOR (0-10 PPM) TO AQ KITINFO2,310.001,155.00
AQ GAS PC SOFTWARE & USB CABLE KIT (FOR AQ MODELS)INFO514.00257.00
AQ H2S-100 UPGRADE TO ADD H2S SENSOR (0-100 PPM) TO AQ KITINFO910.00455.00
AQ NO-250 UPGRADE TO ADD NO SENSOR (0-250 PPM) TO AQ KITINFO910.00455.00
AQ NO2-20 UPGRADE TO ADD NO2 SENSOR (0-20 PPM) TO AQ KITINFO910.00455.00
AQ O3-5 UPGRADE TO ADD O3 SENSOR (0-5 PPM) TO AQEXPERT KITINFO2,310.001,155.00
AQ PRO-1 AIR QUALITY TESTER, CO2/TEMP/HUM/WB/DP/BP/DP/ADD2INFO1,941.00970.50
AQ PRO-2 AIR QUALITY TESTER, CO2/CO/TEMP/HUM/WB/DP/BP/DPINFO1,941.00970.50
AQ SO2-20 UPGRADE TO ADD SO2 SENSOR (0-20 PPM) TO AQ KITINFO906.00453.00
AQ VOC-20 UPGRADE TO ADD VOC SENSOR (0-20 PPM) TO AQ KITINFO3,471.001,735.50
E852130 BLUETOOTH DONGLE FOR PC (FOR AQ MODELS)INFO173.0086.50
E858140 VINYL CARRYING CASE FOR AQ EXPERTINFO1,006.00503.00
E85AACSF13 HANDHELD PROBE (12" W/ 10' HOSE)INFO667.00333.50
EE900P WIRELESS PRINTER (FOR AQ MODELS)INFO675.00337.50
PRO8140 CARRYING CASE (FOR AQ COMFORT AND PRO MODELS)INFO365.00182.50
YAACSM03A RUBBER BOOT (FOR AQ MODELS)INFO187.0093.50

Accessories

No accessories found
Features
  • Real-time continuous data-logging
  • Large internal memory
  • Li-ion rechargeable battery
  • Easy to use menu system
  • Active internal sampling pump
Specifications

AQ COMFORT:

Sensor:

 :CO2 NDIR

 :CO Electrochemical

 :Relative Humidity TFC

 :Ambient Temperature Pt100

 :Differential Pressure Bridge

 :Temperature (Type K T1) Tc K

Range:

 :CO2 0-5,000 ppm

 :CO 0-200 ppm

 :Relative Humidity 5-95%

 :Ambient Temperature -40° to 257℉ (-40° to 125℃)

 :Differential Pressure ±40.0 inH2O (±100.0 mbar)

 :Temperature (Type K T1) 0° to 2000℉ (0° to 1100℃)

Resolution:

 :CO2 1 ppm

 :CO 0.1 ppm

 :Relative Humidity 0.1%

 :Ambient Temperature 0.1℃/℉

 :Differential Pressure 0.1 inH2O (0.25 mbar)

 :Temperature (Type K T1) 1℃/℉

Accuracy:

 :CO2 ±2% rdg. ±10 ppm

 :CO ±1 ppm rdg. ±0.2 ppm

 :Relative Humidity ±2% RH

 :Ambient Temperature ±0.4℃ (0° to 60℃)

 :Differential Pressure ±1% rdg.

 :Temperature (Type K T1) 5℉ (3℃) or 2% of rdg.

Electromagnetic Compatibility:EN-61326-1, portable equipment

AQ VOC:

Sensor:

 :Low Range PID

 :High Range PID

 :Relative Humidity TFC

 :Ambient Temperature Pt100

 :Barometric Pressure Solid State

 :Differential Pressure Bridge

 :Air Velocity Calculated

Range:

 :Low Range 0-20 ppm

 :High Range 0-200 ppm

 :Relative Humidity 5-95%

 :Ambient Temperature -40° to 257℉ (-40° to 125℃)

 :Barometric Pressure 260-1260 mbar

 :Differential Pressure ± 8.0 in H2O

 :Air Velocity 0-300 ft/sec

Resolution:

 :Low Range 1ppb

 :High Range 1 ppm

 :Relative Humidity 0.1% RH

 :Ambient Temperature 0.1℃/℉

 :Barometric Pressure 1 mbar

 :Differential Pressure 0.1 inH2O

 :Air Velocity 1 ft/sec

Accuracy:

 :Low Range 10% rdg. ±20 ppb

 :High Range 10% rdg. ±50 ppb

 :Relative Humidity ±2% RH

 :Ambient Temperature ±4℉

 :Barometric Pressure ±2 mbar

 :Differential Pressure ±1% rdg.