Relays and Contactors

RIB01 and RIB02 Series



Product Bar End
Product Bar End

RIB01 and RIB02 Series

Functional Devices Relay in a Box Dry Contact Input Series RIB01 and RIB02 Series

Functional Devices Relay in a Box Dry Contact Input Series

 

The Functional Devices RIB Series dry contact input is controlled by Class 2 circuits with a dry contact from a BAS controller, thermostat, switch, another relay, or a solid-state switch. The power to energize the RIB Series comes from the load being controlled or a local power source near the relay. The relay contacts are isolated from the input power and the dry contact input.


Products
Filter:

(Wholesale customers, log in for your special pricing)

QtyModelDescriptionIn StockList PriceInternet Price
RIB01BDC DRY CONTACT INPUT RIB, 120VAC, SPDT, 20AIn Stock54.0030.24
RIB01SBCDC ENC RLY, CL2 DRY IN,120VAC PWR, 20A SPDT/ORDINFO96.0053.76
RIB01SBDC DRY CONTACT INPUT RIB, 120V, SPDT, 20A, OVR SWINFO74.0041.44
RIB01SBDC-NC ENC RLY, CL2 DRY INPUT,120VAC PWR, 20A SPST-NC/ORDINFO74.0041.44
RIB02BDC DRY CONTACT INPUT RIB, 208-277VAC, SPDT, 20AIn Stock61.0034.16
RIB02SBCDC ENC RLY,DRY CON IN,208-277VAC PWR, 20A SPDT/ORDINFO97.0054.32
RIB02SBDC DRY CONTACT INPUT RIB, 208-277V, SPDT, 20A, OVR SWINFO75.0042.00
RIB21CDC DRY CONTACT INPUT RIB, 120-277VAC, SPDT, 10AINFO44.0024.64
RIB21CDC-N4 DRY CONTACT INPUT RIB, 120-277V, SPDT, 10A, NEMA 4INFO63.0035.28
RIB21CDC-RD DRY CONTACT INPUT 120-277VAC SPDT 10A; RED HOUSINGIn Stock47.0026.32
RIBD01BDC ENC TD RLY, CL2 DRY INPUT,120VAC PWR, 20A SPDTINFO127.0071.12
RIBD01BDC-DOB ENC TDOB RLY, CL 2 DRY CONTACT,120VAC, 20A SPDTINFO109.8061.49
RIBD02BDC ENC TID RLY, CL2 DRY CONTACT, 208-277VAC, 20A SPDTINFO139.0077.84

Accessories

No accessories found
Features
  • Remote power input, dry contact control
  • LED indication
  • UL listed
  • Optional override switch
Specifications

Coil Rating:120 VAC @ 42 mA, 208-277 VAC @ 62 mA, 120-277 VAC @ 50 mA

Contact Rating:20A resistive @ 277 VAC, 1110 VA pilot duty @ 277 VAC, 770 VA pilot duty @ 120 VAC, 20A ballast 277 VAC, N.O. 10A ballast 277 VAC, N.C 240W tungsten 120 VAC, N.C. 2 hp 277 VAC, 1 hp 120 VAC, 10A general use @ 250 VAC, 10A resistive @ 30 VDC, 1/2 hp 125-250 VAC, 470 VA pilot duty 120-240 VAC

Frequency:50/60 Hz

Controlling Contact:SPST, 7 VDC, 1µA minimum

Output Type:SPDT, SPST-NO

Wire Length:16" (40.6 cm)

Operating Temperature:-30° to 140°F (-34.4° to 60°F)

Operating Humidity:5% to 95% non-condensing

Housing Type:NEMA 1, plemum

Conduit Hub:1/2" NPT

Dimensions:

 :RIB01, RIB02 2.3" H x 3.2" W x 1.8" D

 : (5.8 x 8.1 x 4.6 cm)

 :RIB21CDC 1.7" H x 2.8" W x 1.5" D

 :(4.3 x 7.1 x 3.8 cm)

Approval:UL File E68805

Warranty:1 year

Certifications




Download Additional Data

document   Catalog Page
document   RIB01P Datasheet
document   RIB02P Datasheet