product family specifications
Supply Voltage
Up to 600 VAC RMS available, 50/60Hz
Communication
Modbus RTU or TCP/IP
BACnet IP or MS/TP
LonWorks
Input
Voltage Configuration
3-wire (Delta) or 4-wire (WYE)
CT Input
0-2 VDC current sensors included
Available CT's
5 amp - Up to 3200 Amp RMS AC available
Overload Rating
Voltage Overload +25% continuously; +100% for 20 cycles
Current Sensor Overload 100% for 1 minute without damaging meter
Accuracy
Certified to ANSI C12.20
Range
4 Wire Wye 115/208 VAC: 100, 200, 400, 800, 1600, 3200 Amp
4 Wire Wye 277/480 VAC: 100, 200, 400, 800, 1600, 3200 Amp
3 Wire Delta 220/240 VAC: 100, 200, 400, 800, 1600, 3200 Amp
3 Wire Delta 480 VAC: 100, 200, 400, 800, 1600, 3200 Amp
Operating Temperature
NEMA 4 (Outdoor) Housing: -4° to 158℉ (-20° to 70℃)
NEMA 1 (Indoor) Housing: -4° to 122℉ (-20° to 50℃)
Operating Humidity
0 to 95% RH (non-condensing)
Enclosure Rating
Models with R NEMA 4
Models without R NEMA 12
Dimensions-Meter
7.5"H x 7"W x 3.75"D
(19.1 x 17.8 x 8.3 cm)
Dimensions-Current Sensors Interior Window
100A and 200A = 7/8″ x 1-1/2″
400A = 1-1/2″ x 2-3/4″
800A and 1600A = 3-1/4″ x 4-1/2″
3200A = 5-7/16″ x 7-7/8″
Battery
Non-rechargeable cell used for memory retention
Manufacturer Panasonic
Mfg Part No. CR2032
Working Voltage 3 Vdc
Current Capacity 22.5 mAHr
Electrolyte Mangense Oxide Lithum
Approvals
UL File #E249361
Warranty
1 year
product family features
- Direct-read 8-digit LCD display of cumulative kWh
- Includes 0-2 volt output split-core current sensors
- Remote mounting of current sensors up to 500 feet from meter (using 22 Awg wire)
- Current sensor installation diagnostic indicator
- Available in standard JIC Industrial-grade steel enclosure
- UL Listed; meets or exceeds ANSI C12 national accuracy standards
- Optional power failure contact for alarming
- Dual protocol output
more information & related documents
Family Description
The Honeywell H-Series Class 500 Submeters come with enclosure, display, and does include split core current sensors. Available outputs include pulse, LonWorks, BACnet, BACnet IP, Modbus RTU, or Modbus TCP. There are 38 different points of information available on the communicating models. The dual protocol output allows operation for both RS-485 and Ethernet communication simultaneously. In addition, they will accept up to two pulse inputs from other meters (water, gas, sewer, etc.) and communicate this information as two more data points. Accuracy meets or exceeds +/- 0.5%.