CM6-FCK | Macurco | Gas & Specialty Sensors
CALIBRATION KIT-17L
Brand:Macurco
MPN:CM6-FCK
SKU:CM6-FCK
List Price:
$-.--
Today's Price:
$-.--
product specifications
Type
Calibration Kit
product series specifications
- Supply Voltage:
- 12 to 24 VAC @ 3 VA or 12 to 32 VDC @ 125 mA, reverse polarity protected
- Accuracy:
- ±5% of range
- Supply Current:
- Stand by 23 mA @ 24 VDC
- Fan relay 50 mA @ 24 VDC:
- Both relays (alarm) 75 mA @ 24 VDC:
- Signal Output:
- 4-20 mA @ 900Ω
- Output Range (4-20 mA):
- CM-6:
- 0-200 ppm
- GD6:
- 0-50% L.E.L Methane, Propane, Hydrogen
- TX-6-AM:
- 0-100 ppm NH3
- TX-6-ND:
- 0-20 ppm NO2
- TX-6-HS:
- 0-50 ppm H2S
- OX-6:
- 0-25% v/v
- CD-6:
- 0-2,000PPM
- Life Expectancy:
- 7+ years
- Visual Indication:
- LED (1) Status (green)
- Display 3 digit LED:
- Buzzer:
- 85 dba @ 4‚Ä=(10cm)
- Time Range:
- Fan and Alarm: relay minimum run time: selectable Off (default), 3, 5, 10 or 15 minutes
- Relay Output:
- Fan: 5A, 240 VAC, pilot duty SPDT
- :
- Alarm: 0.5A @ 200Volts, 10 VA, (1 ppm DIF)
- Time Delay:
- Fan and Alarm: Selectable at 0, 1, 3 (default), 5 and 10 minutes
- Wiring Terminations:
- Plugs/terminals
- Operating Temperature:
- 0° to 125°F (-18° to 52°C)
- Operating Humidity:
- 10 to 90% RH
- Enclosure Rating:
- NEMA 1
- Dimensions:
- 4.5"W x 4.0"H x 2.125"D (11.4 x 10.2 x 5.4 cm)
- Weight:
- 1.0 lbs (0.45 Kg)
- Approvals:
- ETL Listed to UL 61010-1, CAN/CSA C22.2 No 61010-1
- Warranty:
- 2 year
product series features
- Easy calibration
- Selectable fan and alarm activation
- Mounts on standard 4x4 electrical box
- Internally supervised system
- Easy functional verification
- Adjustable setpoints
- Digital display
more information & related documents
Series Description
The Macurco™ GD6, TX-6-AM, TX-6-HS, TX-6-ND & OX-6 Series are low voltage, dual relay detectors, controllers and transducers. Each device has selectable 4-20 mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of various gases. The GD6 is a low level meter capable of displaying from 0-50% L.E.L of Methane, Propane or Hydrogen.The TX-6-AM is a low level meter capable of displaying from 0-100 ppm of NH3 (Ammonia). The TX-6-ND is a low level meter capable of displaying from 0-20 ppm of NO2 (Nitrogen Dioxide). The TX-6-HS is a low level meter capable of displaying from 0-50 ppm of H2S (Hyrdogen Sulfide). Kele is the leading supplier of building automation products. When you need the right product, right now, count on Kele.
Kele Description
CALIBRATION KIT-17L
Manufacturer
Macurco