KCD-W-V-T24 | Kele | Gas & Specialty Sensors
Carbon Dioxide Sensor, Wall Mount, 0-10 VDC, 10K Type II
Brand:Kele
MPN:KCD-W-V-T24
SKU:KCD-W-V-T24
List Price:
$306.45
Today's Price:
$159.35
product specifications
Application
Greenhouse, Laboratory, Food & Beverage, IAQ, Parking Garage, Agricultural
Measurement Range
0-2,000 ppm
Output
4-20 mA
Display
No
Options
TEMP
Output Type
0-10 VDC
Mounting Location
Wall
product series specifications
- Supply Voltage:
- 18-28 VAC @ 8 VA, 50/60 Hz, reverse polarity protection or 18-30 VDC @ 330 mA
- Accuracy:
- ±3% of reading or ±40 ppm
- Signal Output:
- 0-10V (10k min.) or 4-20 mA (600Ω max) (0-5V on Duct or wall w/ Temp only)
- Repeatability:
- ±20 ppm
- Measurement Range:
- 0-2000 ppm CO2
- Sensing Technology:
- Non-dispersive IR (NDIR)
- Calibration:
- Push button @ 2000 ppm
- Calibration Interval:
- 5 years
- Life Expectancy:
- 10 years typical
- Visual Indication:
- Green 1000 ppm, Red > 2000 ppm
- Warm Up Time:
- 3 minutes
- Response Time:
- <1 minute
- Temperature:
- Thermistor:
- 10,000Ω Type II & III
- RTD:
- 1,000Ω Platinum 385 curve
- Operating Temperature:
- 31° to 122‚Ñâ (0° to 50‚ÑÉ)
- Operating Humidity:
- 0% to 99% RH (noncondensing)
- Dimensions:
- Wall:
- 4.5"H x 2.8"W x 1.0"D (11.4 x 7.3 x 2.54 cm)
- Duct:
- 4.5"H x 2.8"W x 6.9"D (11.4 x 7.3 x 17.5 cm)
- Duct probe:
- 1.7‚Ä= (4.3 cm) diameter
- :
- 6.25‚Ä= (15.9 cm) long
- Weight:
- Wall:
- 0.25 lb (0.11 Kg)
- Duct:
- 0.5 lb (0.23 Kg)
- Warranty:
- 1 year
product series features
- 24 VAC/VDC power
- 0-10 VDC or 4-20 mA output (0-5VDC on units with temperature option)
- 0-2000 ppm CO2 range
- Wall-mount and duct versions
- Reverse polarity protected
- Simple push-button calibration
- Factory calibrated
- Temperature option
more information & related documents
Series Description
The Kele KCD Series carbon dioxide sensor was designed to offer an economical, reliable, non-dispersive infrared carbon dioxide sensor. The KCD carbon dioxide detector measures environmental CO2 levels for use in demand-controlled ventilation, air-quality monitoring, and other Building Automation Systems, BAS, HVAC applications in accordance with ASHRAE standards. Fully isolated voltage analog outputs and convenient flying leads on the wall mount make installation both simple and trouble-free. The analog output is available in 0-10 Volt DC or 4-20 mA, over the industry standard 0-2000 ppm CO2 range.
Kele Description
CO2 SENSOR WALL VDC 10K OHM TYPE II THMS TEMP
Manufacturer
Kele