Supply Voltage
12-35 VAC ±5% or 12-24 VDC ±10%
Supply Current
60 mA @ 12 VDC
Input Signal
All flow sensors: Excitation voltage 3-wire, 7.9-11.4 VDC, 270Ω source impedance Pulse sensors: Signal amplitude 2.5 VDC threshold, signal limit <35V AC or DC peak, frequency 0-10 kHz, pull-up 8.5 VDC @ 2 kΩ source impedance Sine wave sensors: Signal amplitude 10 mV p-p threshold, signal limit <35V AC or DC peak, frequency 0-10 kHz Temperature sensors: Two matched 10 kΩ @ 25℃, two-wire, type II
Output Signal
-- Output Pulse, isolated solid state switch programmed for units of energy or flow
BN Output BACnet and Modbus communication
LW Output LonWorks communication
N2 Output N2 communication
Pulse Output
Voltage range: 0 to ±60V (DC or AC peak); On-state load current: 700 mA maximum; On-state load resistance: 700 mΩ; Off-state leakage: < 1µA @ 60 V peak; Pulse width: adjustable from .05 to 5.0 seconds
User Interface
Computer connection allows visibility of real-time flow rate, flow total, temperature readings, energy rate and energy total
Communication
BACnet and Modbus, LonWorks, Metasys N2, or Modbus
Configuration
Windows® based A301-20 programming kit (order separately) cable connects to DIC communication port and DB9 COM port on a computer for calibration of flow sensor information, units, output scaling; unit must be powered to configure
Mounting
-00 Enclosure Surface mount, no enclosure
-02 Enclosure Surface mount, in metal enclosure
-03 Enclosure Surface mount, in plastic enclosure
-04 Enclosure DIN rail mount, with clips
Operating Temperature
-20° to 158℉ (-29° to 70℃)
Weight
0.3 lb (0.14 kg) without enclosure
Warranty
1 year
product family features
- AC or DC powered for installation flexibility
- Field programmable makes changes easy
- Small footprint saves space
- Uses two matched 10 KΩ Type II thermistors
- Used with Data Industrial flow sensors
- Bas communication standard
more information & related documents
Family Description
The Badger Meter 340 Series is an inexpensive BTU transmitter that calculates energy usage based on liquid flow rate from a Data Industrial impeller flow sensor, Type II and differential temperature using two 10 kΩ thermistor inputs. The onboard microcontroller provide precise measurements accurate drift-free outputs. Configuration is accomplished with a separately purchased Windows® based software programming kit. The 340 Series comes with onboard communication technology for LonWorks, BACnet, Johnson Controls N2 Metasys, or Modbus networks.