Supply Voltage (If Used): 9 Volt Battery
Readout (Analog, digital etc.): 4 digit LCD back-lit display; 5 minute time out
Dial (white, mirrored, LCD, LED, Stop pins Etc.): 2.5″ diameter w/3/8″ digit height
Window Material (Glass, Polycarbonate etc.): Clear plastic
Indication Scale :Field selectable (PSI, BAR, MPA)
Accuracy: ±0.25% >75psig, ±0.5% >15 psig, Full scale
Calibration (adjustable, Fixed, Etc.): Manual Zero button
Button Controls: Three wipe down buttons
Dial Fill Fluid: On/Unit/Off Controls ON/Off and unit selection
Sensor principle (Balanced, Bourdon tube, Capacitive): Piezoresistive
Operating Pressure Ranges: 15-1,000 PSI (See ordering)
Overpressure (Burst): 10 x Full scale
Max Operating Pressure (Proof): 3 x Full scale
Operating Temperature: 14° to 140℉ (-10° to 60℃)
Operating Humidity: 0 to 95% Non-condensing
Wetted Parts: 316 Stainless Steel (SS) diaphragm
Media Compatibility: Gas or Liquid compatible w/ 316 SS
Process Connection: 1/4″ MNPT
Mounting: By process connection
Wiring Terminations (if needed): None required
Enclosure Case Rating: ABS thermoplastic
Enclosure Rating: NEMA 4X
Dimensions :˜2.5″W x 3.69″L x 1.81″D (6.4 x 9.3 x 4.5cm)
Weight: 1lb. (.45kg)
Approvals: None required
Warranty: 1 Year