Room Pressure Monitor / Transmitter KRPC Series

Room Pressure Monitor / Transmitter

 

The Kele KRPC Series room pressure monitor is used to measure differential pressure in the range of ±0.125″ to 1″WC or ±30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the latest ASIC technology to substantially reduce offset errors due to changes in temperature, stability to warmup, long term instability and position sensitivity. It is ideal for monitoring pressure for air or other clean inert gas. It features field selectable bi-directional pressure ranges and output signal types for the most flexible application. The device has an on-board auto-zero function, backlit LCD and alarm function with silence switch.


Products

(Wholesale customers, log in for your special pricing)

QtyModelDescriptionIn StockList PriceInternet Price
KAA-1 REMOTE AUDIBLE ALARMINFO101.8457.03
KAC PRESSURE PICK UP PORTIn Stock64.7036.23
KRPC1 PRESSURE MONITOR, +/-1.00%, +/-1.00" WC, +/-250 PA, FLD SEL OUT, NO COM, LCDIn Stock1,411.00790.16
KRPC1-AC PRESSURE MONITOR, +/-1.00%, +/-1.00" WC, +/-250 PA, FLD SEL OUT, NO COM, LCDINFO1,481.00829.36
KRPC1-BAC PRESSURE MONITOR, +/-1.00%, +/-1.00" WC, +/-250 PA, FLD SEL OUT, BACNET, LCDINFO1,488.00833.28
KRPC1-BAC-AC PRESSURE MONITOR, +/-1.00%, +/-1.00" WC, +/-250 PA, FLD SEL OUT, BACNET, LCDINFO1,558.00872.48
KRPC1-BAC-SP PRESSURE MONITOR, +/-1.00%, +/-1.00" WC, +/-250 PA, FLD SEL OUT, BACNET, LCDINFO1,558.00872.48
KRPC1-SP PRESSURE MONITOR, +/-1.00%, +/-1.00" WC, +/-250 PA, FLD SEL OUT, NO COM, LCDINFO1,481.00829.36
KRPC2 PRESSURE MONITOR, +/-0.25", +/-0.125" WC, +/-30 PA, +/-60 PA, FLD SEL OUT, NO COM, LCDIn Stock1,411.00790.16
KRPC2-AC PRESSURE MONITOR, +/-0.25", +/-0.125" WC, +/-30 PA, +/-60 PA, FLD SEL OUT, NO COM, LCDINFO1,481.00829.36
KRPC2-BAC PRESSURE MONITOR, +/-0.25", +/-0.125" WC, +/-30 PA, +/-60 PA, FLD SEL OUT, BACNET, LCDINFO1,488.00833.28
KRPC2-BAC-AC PRESSURE MONITOR, +/-0.25", +/-0.125" WC, +/-30 PA, +/-60 PA, FLD SEL OUT, BACNET, LCDINFO1,558.00872.48
KRPC2-BAC-SP PRESSURE MONITOR, +/-0.25", +/-0.125" WC, +/-30 PA, +/-60 PA, FLD SEL OUT, BACNET, LCDINFO1,558.00872.48
KRPC2-SP PRESSURE MONITOR, +/-0.25", +/-0.125" WC, +/-30 PA, +/-60 PA, FLD SEL OUT, NO COM, LCDINFO1,481.00829.36
KRPM STAINLEES STEEL PICK UP PORTIn Stock71.0039.76

Accessories

No accessories found
Features
  • Low pressure monitoring to ±0.125″WC (30 Pa)
  • Four selectable ranges per model
  • Selectable analog output model
  • BACnet communications model
  • Alarm funtions with selectable trip point
  • Easy set up via menu on LCD display
Specifications

Supply Voltage: 24 Vac/dc ±10%, 70 mA max

Signal Output (Volts,Current, Switch): Analog out optional (No BACnet)

Voltage (3w): 0 to (5,10) VDC @2 KΩ min

Current (3w): 4-20mA sourcing, 750Ω max

Alarm Relay:SPST N.O., 2A @120VAC or 30 VDC

ALM. Limits: Adjustable High & Low pressure limits

ALM. Delay: Selectable 0-10 minutes

Setpoint (SP) :Adjust Local Set on touch screen for alarm relay

Control Type: Single room differantial pressure monitor

Communication (if any) :Optional BACnet MS/TP (No analog out)

Field Interface Devices (order Separately): RPS SS room pressure probe

Display/Audible (If any): Red LED for alarm

Display: 3- digit backlit LCD, 0.45″H, (WC or Pa)

Audible (Internal): 85㏈ buzzer w/silence button, (Selectable volume)

Audible Output: 24VDC @20mA max

Accuracy: Auto zero internal push button

± 1% F.S. from (±1″ to ±0.25″) WC:

± 2% F.S. at ±0.125″ WC:

Resolution :Averaging from 1-60 sec., menu selectable (5s default)

Sensor Type: ASIC silicon sensor

Normal Measurement Range: High/Low range selected by order

High Range Field selectable: ± 1.0″ or ± 0.5″ WC, (±250 Pa or ±125 Pa)

Low Range Field selectable: ± 0.25″ or ± 0.125″ WC, (±60 Pa or ±30 Pa)

Overpressure (Burst): 200″WC (49.8 kPa)

Max Operating Pressure (Proof): 100″WC (24.9 kPa)

Operating Temperature: 32° to 140℉ (0° to 60℃)

Operating Humidity: 10-90% RH non-condensing

Wetted Parts: Silicone

Media Compatibility :Inert dry air

Process Connection: Two-1/8″ ID ports w/Adapters, for 1/4″ OD tubing

Wiring Terminations: 5-8 Terminals (14-22 AWG)

Mounting :Slotted back plate for surface or BB wall mount

Enclosure Rating: NEMA 1 (IP30), White ABS plastic

Dimensions: 3.3″W x 4.7″H x 1.15″D, (8.4 x 11.9 x 2.9 cm)

Weight: 0.25 lb (0.11 kg)

Approvals :CE, RoHS

Warranty: 1 year

Certifications