Power Monitoring and Protection

H-Series Class 500 Submeters



Product Bar End
Product Bar End

H-Series Class 500 Submeters

Advanced KWH/DEMAND Meter H-Series Class 500 Submeters

Advanced KWH/DEMAND Meter

 

The Honeywell H-Series Class 500 Submeters come with enclosure, display, and does include split core current sensors. Available outputs include pulse, LonWorks, BACnet, BACnet IP, Modbus RTU, or Modbus TCP. There are 38 different points of information available on the communicating models. The dual protocol output allows operation for both RS-485 and Ethernet communication simultaneously. In addition, they will accept up to two pulse inputs from other meters (water, gas, sewer, etc.) and communicate this information as two more data points. Accuracy meets or exceeds +/- 0.5%.


Products

(Wholesale customers, log in for your special pricing)

QtyModelDescriptionIn StockList PriceInternet Price
E10010 100 AMP 0-2V SPLIT CORE SENSOR 3 PIECE SETINFO703.09351.55
E10011 1600 AMP 0-2V SPLIT CORE CURRENT SENSOR 3 PC SETINFO989.22494.61
E10012 200 AMP 0-2V SPLIT CORE CURRENT SENSOR 3 PIECE SETINFO744.60372.30
E10014 3200 AMP 0-2V SPLIT CORE SENSOR 3 PIECE SETINFO1,198.46599.23
E10015 400 AMP 0-2V SPLIT CORE SENSOR 3 PIECE SETINFO744.60372.30
E10017 800 AMP 0-2V SPLIT CORE SENSOR 3 PIECE SETINFO989.22494.61
E50-208100-J02KIT 120/208-240V 100A JIC MBUS RTU EZ-7 3SC CURR SENSINFO3,411.201,705.60
E50-208100-R01KIT 120/208-240V 100A NEMA EZ-7 MBUS 3 SC CURR SENSINFO2,714.381,357.19
E50-208100-R02KIT 120/208-240V 100A NEMA MBUS RTU EZ-7 3 SC CUR SENINFO3,411.201,705.60
E50480100J5KTNS 277/480V 100A JIC EZ-7 BACNET IP NO 2V OUTPUTINFO3,388.151,694.08
E504801600J5KNS 277/480V 1600A JIC EZ7 BACNET IP NO 2V OUTPUTINFO3,744.781,872.39
E50480200J05KNS 277/480V 200A JIC EZ-7 BACNET IP NO 2V OUTPUTINFO3,388.151,694.08
E504803200J5KNS 277/480V 3200A JIC EZ-7 BACNET IP NO 2V OUTPUTINFO4,475.642,237.82
E50480400J5KTNS 277/480V 400A JIC EZ-7 BACNET IP NO 2V OUTPUTINFO3,388.151,694.08
E50480800J5KTNS 277/480V 800A JIC EZ7 BACNET IP NO 2V OUTPUTINFO3,744.781,872.39

Accessories

No accessories found
Features
  • Direct-read 8-digit LCD display of cumulative kWh
  • Includes 0-2 volt output split-core current sensors
  • Remote mounting of current sensors up to 500 feet from meter (using 22 Awg wire)
  • Current sensor installation diagnostic indicator
  • Available in standard JIC Industrial-grade steel enclosure
  • UL Listed; meets or exceeds ANSI C12 national accuracy standards
  • Optional power failure contact for alarming
  • Dual protocol output
Specifications

Supply Voltage :Up to 600 VAC RMS available, 50/60Hz

Communication:

 :Modbus RTU or TCP/IP

 :BACnet IP or MS/TP

 :LonWorks

Input :

Voltage Configuration:3-wire (Delta) or 4-wire (WYE)

CT Input: 0-2 VDC current sensors included

Available CT's:5 amp - Up to 3200 Amp RMS AC available

Overload Rating:

 :Voltage Overload +25% continuously; +100% for 20 cycles

 :Current Sensor Overload 100% for 1 minute without damaging meter

Accuracy:Certified to ANSI C12.20

Range:

 :4 Wire Wye 115/208 VAC: 100, 200, 400, 800, 1600, 3200 Amp

 :4 Wire Wye 277/480 VAC: 100, 200, 400, 800, 1600, 3200 Amp

 :3 Wire Delta 220/240 VAC: 100, 200, 400, 800, 1600, 3200 Amp

 :3 Wire Delta 480 VAC: 100, 200, 400, 800, 1600, 3200 Amp

Operating Temperature:

 :NEMA 4 (Outdoor) Housing: -4° to 158℉ (-20° to 70℃)

 :NEMA 1 (Indoor) Housing: -4° to 122℉ (-20° to 50℃)

Operating Humidity:0 to 95% RH (non-condensing)

Enclosure Rating:

 :Models with R NEMA 4

 :Models without R NEMA 12

Dimensions-Meter:7.5"H x 7"W x 3.75"D

(19.1 x 17.8 x 8.3 cm):

Dimensions-Current Sensors Interior Window:

 :100A and 200A = 7/8″ x 1-1/2″

 :400A = 1-1/2″ x 2-3/4″

 :800A and 1600A = 3-1/4″ x 4-1/2″

 :3200A = 5-7/16″ x 7-7/8″

Battery:Non-rechargeable cell used for memory retention

 :Manufacturer Panasonic

 :Mfg Part No. CR2032

 :Working Voltage 3 Vdc

 :Current Capacity 22.5 mAHr

 :Electrolyte Mangense Oxide Lithum

Approvals:UL File #E249361

Warranty:1 year

Certifications