Network and Wireless

BA/COM, BA/ROM, BA/RYOM, BA/RYOL, BA/SOM, BA/VOM



Product Bar End
Product Bar End

BA/COM, BA/ROM, BA/RYOM, BA/RYOL, BA/SOM, BA/VOM

BAPI Wireless System Output Modules BA/COM, BA/ROM, BA/RYOM, BA/RYOL, BA/SOM, BA/VOM

BAPI Wireless System Output Modules

 

The BAPI BA/ROM, VOM, COM, and RYOM wireless system output modules are specifically designed to connect to any BA/RCV receiver and communicate over an RS485 communication trunk to generate standard output signals for any BAS system. A total of 127 modules may be interspersed on the RS485 trunk. Each will output a signal representative of its assigned remotely located wireless transmitter. Each module may be powered from the receiver power bus, or individually, based on overall system power requirements. The BAPI BA/ROM thermistor simulation output module converts a wireless transmitter temperature signal according to a standard thermistor curve. The three standard curves are 10 KΩ Type 3, a 10 KΩ Type 2, with a resistance temperature response of 35° to 120°F (1° to 50°C) and a 20 K thermister curve with response of 50° to 120℉ (12° to 50℃). The BAPI BA/VOM voltage output module converts a wireless transmitter temperature signal to a standard voltage signal. The two standard voltage outputs are 0-5 VDC and 0-10 VDC, with voltage temperature responses based on individual models. The BAPI BA/COM current output module converts a wireless transmitter temperature signal to a standard 4-20 mA current signal. The 4-20 mA current is typical of a loop powered (9-36 VDC) device with current temperature responses based on individual models. The BAPI BA/RYOM digital output module converts the pushbutton on a wireless room temperature transmitter to a solid-state relay momentary closure for AC or DC voltages (5 second momentary actuation). NO or NC solid-state contacts are available, based on individual models. The BAPI BA/RYOL digital output module converts the BA/WDI digital input transmitter signal to a latching relay output. NO or NC fail safe contacts are available, based on individual models. The BAPI BA/SOM setpoint output module converts the setpoint data received to a resistance or voltage output.


Products
Filter:

(Wholesale customers, log in for your special pricing)

QtyModelDescriptionIn StockList PriceInternet Price
BA/AOM-CONN PLUGGABLE TERMINAL BLOCK KIT FOR AOM In Stock16.0412.83
BA/BP2 BP2 BACK PLANE 2 POSITION INFO42.5534.04
BA/COM-C-C-EZ WIRELESS OUTPUT MODULE 4-20MA 10 TO 32C INFO244.92195.94
BA/COM-D CURRENT OUTPUT MODULE INFO200.30160.24
BA/DS6R-10K DRY CONTACT MONITOR 10K OUTPUT INFO131.80105.44
BA/COM-C-EZ 4-20 MA O/P MOD,50 TO 90 F,DIN INFO187.06149.65
BA/COM-D-EZ 4-20 MA O/P MOD,55 TO 85 F,DIN INFO187.06149.65
BA/COM-E-EZ 4-20 MA O/P MOD,60 TO 80 F,DIN INFO187.06149.65
BA/COM-F-EZ 4-20 MA O/P MOD,65 TO 80 F,DIN INFO187.06149.65
BA/COM-H-EZ 4-20 MA O/P MOD,-20 TO 120 F,DIN In Stock187.06149.65
BA/COM-KK-EZ 4-20 MA O/P MOD,32 TO 185 F,DIN INFO187.06149.65
BA/COM-M-EZ 4-20 MA O/P MOD,0-100% RH,DIN INFO187.06149.65
BA/COM-MM-EZ 4-20 MA O/P MOD,-40 TO 140 F,DIN INFO187.06149.65
BA/COM-N-EZ 4-20 MA O/P MOD,35-70% RH,DIN INFO187.06149.65
BA/EZ-ROM-102 RESISTANCE O/P MOD,10K TYPE 24,DIN INFO187.06149.65
BA/RYOM-NC-EZ RELAY O/P MOD,NC,MOMENTARY,DIN INFO187.06149.65
BA/RYOM-NO-EZ RELAY O/P MOD,NO,MOMENTARY,DIN INFO187.06149.65
BA/SOM-00-EZ S/P O/P MOD,0-5V O/P,DIN In Stock187.06149.65
BA/SOM-01-EZ S/P O/P MOD,1-5V O/P,DIN INFO187.06149.65
BA/SOM-02-EZ S/P O/P MOD,3.7-.85V O/P,DIN INFO187.06149.65
BA/SOM-03-EZ S/P O/P MOD,5-0V O/P,DIN INFO187.06149.65
BA/SOM-04-EZ S/P O/P MOD,4.2-1.2V O/P,DIN INFO187.06149.65
BA/SOM-05-EZ S/P O/P MOD,2.75-3.34V O/P,DIN INFO187.06149.65
BA/SOM-06-EZ S/P O/P MOD,2.88-3.17V O/P,DIN INFO187.06149.65
BA/SOM-10-EZ S/P O/P MOD,0-10V O/P,DIN INFO182.79146.23
BA/SOM-11-EZ S/P O/P MOD,2-10V O/P,DIN INFO187.06149.65
BA/SOM-50-EZ S/P O/P MOD,0 TO 5K OHM O/P,DIN INFO187.06149.65
BA/SOM-51-EZ S/P O/P MOD,7.87K TO 2.87K OHM O/P,DIN INFO187.06149.65
BA/SOM-60-EZ S/P O/P MOD,0 TO 10K OHM O/P,DIN INFO187.06149.65
BA/SOM-61-EZ S/P O/P MOD,15K TO 5K OHM O/P,DIN INFO187.06149.65
BA/SOM-62-EZ S/P O/P MOD,9,577 TO 1,422 OHM O/P,DIN INFO187.06149.65
BA/SOM-63-EZ S/P O/P MOD,1K TO 11K OHM O/P,DIN INFO187.06149.65
BA/SOM-80-EZ S/P O/P MOD,0 TO 20K OHM O/P,DIN INFO187.06149.65
BA/SOM-81-EZ S/P O/P MOD,4.75K TO 24.75K OHM O/P,DIN INFO187.06149.65
BA/SOM-82-EZ S/P O/P MOD,6.19K TO 26.19K OHM O/P,DIN INFO187.06149.65
BA/SOM-83-EZ S/P O/P MOD,7.87K TO 27.87K OHM O/P,DIN INFO187.06149.65
BA/SOM-84-EZ S/P O/P MOD,10K TO 30K OHM O/P,DIN INFO187.06149.65
BA/SOM-85-EZ S/P O/P MOD,24.75K TO 4.75K OHM O/P,DIN INFO187.06149.65
BA/VOM-05-C-EZ 0-5V O/P MOD,50 TO 90 F,DIN INFO187.06149.65
BA/VOM-05-D-EZ 0-5V O/P MOD,55 TO 85 F,DIN INFO187.06149.65
BA/VOM-05-E-EZ 0-5V O/P MOD,60 TO 80 F DIN INFO187.06149.65
BA/VOM-05-F-EZ 0-5V O/P MOD,65 TO 80 F INFO187.06149.65
BA/VOM-05-H-EZ 0-5V O/P MOD,-20 TO 120 F,DIN INFO187.06149.65
BA/VOM-05-KK-EZ 0-5V O/P MOD,32 TO 185 F,DIN INFO187.06149.65
BA/VOM-05-M-EZ 0-5V O/P MOD,0-100% RH,DIN INFO187.06149.65
BA/VOM-05-MM-EZ 0-5V O/P MOD,-40 TO 140 F,DIN In Stock187.06149.65
BA/VOM-05-N-EZ 0-5V O/P MOD,35-70% RH,DIN INFO187.06149.65
BA/VOM-10-C-EZ 0-10V O/P MOD,50 TO 90 F,DIN INFO182.79146.23
BA/VOM-10-D-EZ 0-10V O/P MOD,55 TO 85 F,DIN INFO187.06149.65
BA/VOM-10-E-EZ 0-10V O/P MOD,60 TO 80 F,DIN INFO187.06149.65
BA/VOM-10-F-EZ 0-10V O/P MOD,65 TO 80 F,DIN INFO187.06149.65
BA/VOM-10-H-EZ 0-10V O/P MOD,-20 TO 120 F,DIN INFO182.79146.23
BA/VOM-10-KK-EZ 0-10V O/P MOD,32 TO 185 F,DIN INFO187.06149.65
BA/VOM-10-M-EZ 0-10V O/P MOD,0-100% RH,DIN INFO187.06149.65
BA/VOM-10-MM-EZ 0-10V O/P MOD,-40 TO 140 F,DIN INFO182.79146.23
BA/VOM-10-N-EZ 0-10V O/P MOD,35-70% RH,DIN INFO187.06149.65
BA/EZ-COM-H-C 4-20 MA OUTPUT -29 TO 49C TE INFO210.68168.54
BA/LI3620 AA LITHIUM 36V BATTERY INFO38.4930.79
BA/RYOL-NO-EZ RELAY OUTPUT, LATCHING, DEFAULT TO NORMALLY OPN INFO187.06149.65
BA/SFC2000-100 BLUE TWIST-ON CONNECTOR 100 PCS. INFO219.13175.30
BA/TS1 TS1 TRANSIENT SUPPRESSOR BI-POLAR INFO10.238.18
BA/TURB-TRK TURB TERMINAL UNIT RELAY BOARD W/TRACK INFO114.1591.32
BA/VC3000A-FW 2.5 AMP VOLT CONVER 18-30 AC/DC FUL WAVE NO BK PLA INFO166.05132.84
BA/VC3000B-FW 2.5 AMP VOLT CONVERT 18-30 AC/DC FUL WAVE W/BK PLA INFO166.05132.84
BA/VC350A-15 350MA AC TO DC VOLTAGE CONVERTER INFO49.8239.86
BA/VC350A-ADJ 350 MA VOLTAGE CONV ADJ OUTPUT TRACK MOUNTABLE In Stock47.2237.78
BA/VC350A-ADJ-T 350 MA VOLTAGE CONV ADJ OUTPUT WITH SNAP TRACK In Stock56.6745.34
BA/VC350A-EZ-ADJ 350 MA VOLTAGE CONV EZ HOUSING ADJ OUTPUT In Stock41.9833.58
BA/VOM-10-M VOLTAGE OUTPUT MODULE INFO205.48164.38
BA/VOM-05-D VOLTAGE OUTPUT MODULE INFO210.68168.54
BA/VOM-05-G VOLTAGE OUTPUT MODULE INFO205.48164.38
BA/VOM-05-M VOLTAGE OUTPUT MODULE INFO205.48164.38
BA/WT-RPFEP-15 REM PRB W/ FEP JACKETED CABLE,15FT LDS INFO422.90338.32
BA/WT-RPFEP-20 REM PRB W/ FEP JACKETED CABLE,20FT LDS INFO428.78343.02
BA/WT-RPFEP-25 REM PRB W/ FEP JACKETED CABLE,25FT LDS INFO434.68347.74
BA/WT-TB-M304-2-BB WIRELESS THOMOBUFFER,SS,2IN PROBE INFO640.29512.23
BA/WT-TB-M304-4-BB WIRELESS THOMOBUFFER,SS,4IN PROBE INFO614.74491.79
BA/WT-TB-MAL-2-BB WIRELESS THOMOBUFFER,ALUM,2IN PROBE INFO545.40436.32
BA/WT-TB-MAL-4-BB WIRELESS THOMOBUFFER,ALUM,4IN PROBE INFO545.40436.32

Accessories

No accessories found
Features
  • Provide BAS point wiring
  • 127 modules per system
  • Thermistor simulation for temperature
  • 0-10 VDC, 0-5 VDC, or 4-20 mA signals
  • Solid-state contacts
  • Built-in fail-safe on signal loss
  • Snap-track and DIN rail mounting
Specifications

Device Operation:

Supply Voltage:Most modules powered from BA/RCV receiver

VOM, ROM:Powered from reciever bus

RYOx, SOM:Powered from reciever bus

COM:9-36 VDC from current loop

Output:RS485 bus to a maximum of 127 ″Output Modules″

BA/VOM-xx:0-5V or 0-10V @10KO

BA/COM-xx:4-20mA, 750O @24VDC

BA/SOM-xx:0-5V or 0-10V @10KO, or Resistance 0-75K

BA/ROM-xxx:Thermistor (10K-2, 10K-3, 20K)

BA/RYOM:Momentary, Triac, 40V AC/DC, 150mA, 1µA leakage

BA/RYOL:Latching, Triac, 40V AC/DC, 150mA, 1µA leakage

Indication:LED blinks on each reception

A/D resolution:10 bit, 1024 counts″

Mounting:DIN rail or 2 screws to back plane

and/or other output modules :

Wiring:2 field terminals, 22-16 AWG

Operating Temperature:32 to 140℉ (0 to 60℃)

Operating Humidity:5-95% RH non-condensing

Construction:ABS Plastic, UL94V-0

Enclosure Rating:Indoor, NEMA 1

Dimensions:2.75″H x 2.34″W x 1.2″D, (7.0 x 5.9 x 3.0 cm)

Weight:0.3 lb (0.14 Kg)

Warranty:2 year

Radio/Radio Receiver Interface:

Update Interval:Updates on each reception

Lost Comm. Fail Safe:If no reception >15 minutes modules fail safe

BA/VOM-xx:℉ Fails low and %RH Fails high

BA/COM-xx:℉ Fails low and %RH Fails high

BA/SOM-xx:℉ Fails low

BA/ROM-xx:℉ Fails low

BA/RYOM :Fails to the normal condition per order (NO or NC)

BA/RYOL:Fails to the normal condition per order (NO or NC)

Programming:Push button on ″Transmitter/Output Module″ simultaneously

Approvals:RoHS

Certifications