Motor Controls

SMARTVFD HVAC With Bypass Assembly



Product Bar End
Product Bar End

SMARTVFD HVAC With Bypass Assembly

Variable Frequency Drives with Bypass SMARTVFD HVAC With Bypass Assembly

Variable Frequency Drives with Bypass

 

Honeywell's integral bypass and disconnect system make applying the SmartVFD drive a snap. Available with a simple fused disconnect switch, a 2-contactor bypass assembly, or a 3-contactor bypass assembly, it simplifies installation. All the features of the SmartVFD are included – a wide array of configurable inputs and outputs, and all the most popular network protocols, and the super easy startup wizards that speed commissioning. All drives feature Hand-Off-Auto operation as a is fully integrated keypad function. Make the SmartVFD choice for your variable speed drive needs.


Products
Filter:

(Wholesale customers, log in for your special pricing)

QtyModelDescriptionIn StockList PriceInternet Price
32006628-001/U NXS,DISPLAYKITFORNEMA12INFO674.00377.44
32006629-001/U NXS,DISPLAYBLANKPANELINFO84.0047.04
32006629-004/U NX,RS232ADAPTERINFO350.00196.00
32006630-001/U SMARTDRIVEHVAC,LONCOMM.CARDINFO952.00533.12
32006630-002/U NX,COMMUNICATIONCARD,N2,MODBUSINFO1,016.00568.96
32006630-013/U NX,BACNETCOMMUNICATIONCARDINFO444.00248.64

Accessories

No accessories found
Features
  • Ideal for low and high hp fans and pumps
  • Disconnect, 2-, or 3-contactor bypass
  • Fused disconnect
  • Auto bypass available
  • Available in NEMA 1, 12, or 3R enclosure types
  • Compact size
  • SmartVFD wizard for pump or fan control
  • Intuitive commissioning
  • High resolution graphic interface
  • User manual built in to firmware
Specifications

Supply Voltage:208 VAC ±10%, 3 phase, 47 - 66 Hz

 :230 VAC ±10%, 3 phase, 47 - 66 Hz

 :480 VAC ±10%, 3 phase, 47 - 66 Hz

Motor Rating: 1.0 to 250 HP

Frequency Range:0 - 320 Hz

Acceleration Time:Adjustable 0.1 - 3000 seconds

Deceleration Time:Adjustable 0.1 - 3000 seconds

Digital Inputs:6 factory preset

Analog Input:2; 0-10V or 4-20 mA programmable

Digital Output:Open collector, max. load 48V / 50 mA

Analog Output:1; 4-20 mA

Relay Outputs:2 each SPDT 8A at 24 VDC or 250 VAC 0.4A at 125 VDC Minimum load 10Ma at 5 VAC/VDC

Filter Type:5% DC choke , and class 2 GMC/RFI

EMC:Complies with EN50082-1, -2

Communication Protocol:

RS485:BACnet MS/TP, N2, Modbus

Ethernet:BACnet/ IP, Modbus/TCP

Switch Controls:4-Position (Bypass, Off, Test, VFD)

Lamp Indication:Bypass Run (Yellow), VFD Run (Green)

Graphic Display:LCD for menu setup

Button Controls:5 button for setup

Operating Temperature:14° to 104℉ (-10° to 40℃)

Operating Humidity:0 to 95% RH (non-condensing)

Approvals:UL Listed File #E190898 cUL CE RoHS

Warranty:3 years

Certifications