Level

LDT Series



Product Bar End
Product Bar End

LDT Series

BAPI Water Leak Detector LDT Series

BAPI Water Leak Detector

 

The BAPI LDT Series water leak detectors are designed to sense the presence of water and alert a central monitoring system of the potentially destructive situation. The detector can be set for latching or non-latching alarm, and normally energized or normally de-energized operation.


Products

(Wholesale customers, log in for your special pricing)

QtyModelDescriptionIn StockList PriceInternet Price
BA/LDT1-PS-BB LEAK DET 0.5A RELAY INTEGRAL SENSOR In Stock209.29167.43
BA/LDT1-RR10-BB LEAK DET 0.5A RELAY REM 10FT SENSOR PLENUM In Stock395.68316.54
BA/LDT1-RR100-BB LEAK DET 0.5A RELAY REM 100FT SENSOR PLENUM INFO2,066.921,653.54
BA/LDT1-RR25-BB LEAK DET 0.5A RELAY REM 25FT SENSOR PLENUM In Stock640.38512.30
BA/LDT1-RR50-BB LEAK DET 0.5A RELAY REM 50FT SENSOR PLENUM INFO1,103.74882.99
BA/LDT1-RS10-BB LEAK DET 0.5A RELAY REM 10FT SENSOR In Stock221.79177.43
BA/LDT1-RS25-BB LEAK DET 0.5A RELAY REM 25FT SENSOR INFO241.58193.26
BA/LDT1-RS5-BB LEAK DET 0.5A RELAY REM 5FT SENSOR In Stock214.50171.60
BA/LDT2-PS-BB LEAK DET TWO 0.5A RELAYS INTEGRAL SENSOR In Stock222.83178.26
BA/LDT2-RR10-BB LEAK DET TWO 0.5A RELAYS REM 10FT SENSOR PLENUM INFO406.10324.88
BA/LDT2-RR100-BB LEAK DET TWO 0.5A RELAYS REM 100FT SENSOR PLENUM INFO2,071.081,656.86
BA/LDT2-RR25-BB LEAK DET TWO 0.5A RELAYS REM 25FT SENSOR PLENUM INFO647.66518.13
BA/LDT2-RR50-BB LEAK DET TWO 0.5A RELAYS REM 50FT SENSOR PLENUM INFO1,114.16891.33
BA/LDT2-RS10-BB LEAK DET TWO 0.5A RELAYS REM 10FT SENSOR In Stock234.98187.98
BA/LDT2-RS25-BB LEAK DET TWO 0.5A RELAYS REM 25FT SENSOR INFO254.90203.92
BA/LDT2-RS5-BB LEAK DET TWO 0.5A RELAYS REM 5FT SENSOR INFO228.03182.42
BA/LDT2-PS-BB-LTF LEAK DET TWO 0.5A RELAYS INTEGRAL SENSOR LT FIT INFO460.00368.00
BA/LDT3-PS-BB LEAK DET 5A RELAY INTEGRAL SENSOR INFO217.62174.10
BA/LDT3-RR10-BB LEAK DET 5A RELAY REM 10FT SENSOR PLENUM INFO409.22327.38
BA/LDT3-RR100-BB LEAK DET 5A RELAY REM 100FT SENSOR PLENUM INFO2,072.131,657.70
BA/LDT3-RR25-BB LEAK DET 5A RELAY REM 25FT SENSOR PLENUM In Stock650.80520.64
BA/LDT3-RR50-BB LEAK DET 5A RELAY REM 50FT SENSOR PLENUM INFO1,119.37895.50
BA/LDT3-RS10-BB LEAK DET 5A RELAY REM 10FT SENSOR INFO229.08183.26
BA/LDT3-RS25-BB LEAK DET 5A RELAY REM 25FT SENSOR INFO248.86199.09
BA/LDT3-RS5-BB LEAK DET 5A RELAY REM 5FT SENSOR INFO222.83178.26
BA/LDT4-PS-BB LEAK DET TWO 5A RELAYS INTEGRAL SENSOR In Stock230.12184.10
BA/LDT4-RR10-BB LEAK DET TWO 5A RELAYS REM 10FT SENSOR PLENUM INFO414.42331.54
BA/LDT4-RR100-BB LEAK DET TWO 5A RELAYS REM 100FT SENSOR PLENUM INFO2,077.331,661.86
BA/LDT4-RR25-BB LEAK DET TWO 5A RELAYS REM 25FT SENSOR PLENUM INFO652.87522.30
BA/LDT4-RR50-BB LEAK DET TWO 5A RELAYS REM 50FT SENSOR PLENUM INFO1,129.78903.82
BA/LDT4-RS10-BB LEAK DET TWO 5A RELAYS REM 10FT SENSOR INFO242.61194.09
BA/LDT4-RS25-BB LEAK DET TWO 5A RELAYS REM 25FT SENSOR INFO262.40209.92
BA/LDT4-RS5-BB LEAK DET TWO 5A RELAYS REM 5FT SENSOR INFO236.37189.10
BA/LTD2-RR25-BB-LTF LEAK DET TWO 0.5A RELAYS REM 25FT PLEN LT FIT INFO748.00598.40
BA/LTD4-PS-BB-LTF LEAK DET TWO 5A RELAYS INTEGRAL SENSOR LT FITTING INFO242.00193.60

Accessories

No accessories found
Features
  • Detection within 5 seconds with local LED indication
  • One piece, rope, or remote sensor designs
  • Adjustable detection level
  • NEMA 4 enclosure
Specifications

Materials Of Construction:Sensor: Stainless Steel

Bapi-Box: Polycarbonate:

Enclosure Rating:Remote Sensor: Submersible, with FEP plenum-rated, waterproof cable

Detector: BAPI-Box, NEMA 4:

Mounting: Lays in the pan with industrial adhesive tape or attached to the pan edge with screws

Wiring: Flex connector or liquid tight fitting; Relays: up to 6 wires for alarm contacts; Transmitter: 2 wires for power

Indicator: 1 green power LED; 1 red alarm LED

Sensor: Attached SS probe w/ adjustable depth screw from 0.063″ to 0.84″

Latching and Supervised Relay Options:

Latching:Relay stays in alarm until manually reset or power in cycled

Non-Latching:Relay automatically resets after water has dried up (default)

Unsupervised:Relay energizes on water detection

Supervised:Relay de-energizes on water detection (default); Note: relay de-energizes on loss of power

Ambient Temperature:

Remote Sensor:-40° to 185℉ (-40° to 85℃)

Rope Sensor:32° to 167℉ (0° to 75℃)

Detector (BB):-40° to 185℉ (-40° to 85℃)

Ambient Humidity:

Remote Sensor:0% to 100%, condensing

Rope Sensor:0% to 95%, non-condensing

Detector (BB):0% to 95%, non-condensing

Power:18-30 VAC ~4 VA

Reset:If latching, local push button or power interrupt

Terminations:Terminal strip, 12-24 AWG

Approvals:RoHS, UL94V-0 , UV-rated in Enclosure

Weight:0.5 lb (0.2 kg)

Certifications


Download Additional Data

document   BAPI LDT Install
document   BAPI Water Leak Detector Data Sheet