Level

LDT Series



Product Bar End
Product Bar End

LDT Series

BAPI Water Leak Detector LDT Series

BAPI Water Leak Detector

 

The BAPI LDT Series water leak detectors are designed to sense the presence of water and alert a central monitoring system of the potentially destructive situation. The detector can be set for latching or non-latching alarm, and normally energized or normally de-energized operation.


Products

(Wholesale customers, log in for your special pricing)

QtyModelDescriptionIn StockList PriceInternet Price
BA/LDT1-PS-BB LEAK DET 0.5A RELAY INTEGRAL SENSORIn Stock217.74108.87
BA/LDT1-RR10-BB LEAK DET 0.5A RELAY REM 10FT SENSOR PLENUMIn Stock411.65205.83
BA/LDT1-RR100-BB LEAK DET 0.5A RELAY REM 100FT SENSOR PLENUMINFO2,150.371,075.18
BA/LDT1-RR25-BB LEAK DET 0.5A RELAY REM 25FT SENSOR PLENUMINFO666.24333.12
BA/LDT1-RR50-BB LEAK DET 0.5A RELAY REM 50FT SENSOR PLENUMINFO1,148.30574.15
BA/LDT1-RS10-BB LEAK DET 0.5A RELAY REM 10FT SENSORIn Stock230.74115.37
BA/LDT1-RS25-BB LEAK DET 0.5A RELAY REM 25FT SENSORINFO251.33125.67
BA/LDT1-RS5-BB LEAK DET 0.5A RELAY REM 5FT SENSORIn Stock223.16111.58
BA/LDT2-PS-BB LEAK DET TWO 0.5A RELAYS INTEGRAL SENSORINFO231.83115.91
BA/LDT2-RR10-BB LEAK DET TWO 0.5A RELAYS REM 10FT SENSOR PLENUMINFO422.49211.25
BA/LDT2-RR100-BB LEAK DET TWO 0.5A RELAYS REM 100FT SENSOR PLENUMINFO2,154.701,077.35
BA/LDT2-RR25-BB LEAK DET TWO 0.5A RELAYS REM 25FT SENSOR PLENUMINFO673.81336.90
BA/LDT2-RR50-BB LEAK DET TWO 0.5A RELAYS REM 50FT SENSOR PLENUMINFO1,159.14579.57
BA/LDT2-RS10-BB LEAK DET TWO 0.5A RELAYS REM 10FT SENSORINFO244.46122.23
BA/LDT2-RS25-BB LEAK DET TWO 0.5A RELAYS REM 25FT SENSORINFO265.19132.59
BA/LDT2-RS5-BB LEAK DET TWO 0.5A RELAYS REM 5FT SENSORINFO237.24118.62
BA/LDT2-PS-BB-LTF LEAK DET TWO 0.5A RELAYS INTEGRAL SENSOR LT FITIn Stock478.57239.29
BA/LDT3-PS-BB LEAK DET 5A RELAY INTEGRAL SENSORINFO226.41113.20
BA/LDT3-RR10-BB LEAK DET 5A RELAY REM 10FT SENSOR PLENUMINFO425.74212.87
BA/LDT3-RR100-BB LEAK DET 5A RELAY REM 100FT SENSOR PLENUMINFO2,155.791,077.89
BA/LDT3-RR25-BB LEAK DET 5A RELAY REM 25FT SENSOR PLENUMINFO677.08338.54
BA/LDT3-RR50-BB LEAK DET 5A RELAY REM 50FT SENSOR PLENUMINFO1,164.56582.28
BA/LDT3-RS10-BB LEAK DET 5A RELAY REM 10FT SENSORINFO238.33119.17
BA/LDT3-RS25-BB LEAK DET 5A RELAY REM 25FT SENSORINFO258.91129.45
BA/LDT3-RS5-BB LEAK DET 5A RELAY REM 5FT SENSORINFO231.83115.91
BA/LDT4-PS-BB LEAK DET TWO 5A RELAYS INTEGRAL SENSORIn Stock239.41119.70
BA/LDT4-RR10-BB LEAK DET TWO 5A RELAYS REM 10FT SENSOR PLENUMINFO431.15215.58
BA/LDT4-RR100-BB LEAK DET TWO 5A RELAYS REM 100FT SENSOR PLENUMINFO2,161.201,080.60
BA/LDT4-RR25-BB LEAK DET TWO 5A RELAYS REM 25FT SENSOR PLENUMINFO679.23339.61
BA/LDT4-RR50-BB LEAK DET TWO 5A RELAYS REM 50FT SENSOR PLENUMINFO1,175.39587.70
BA/LDT4-RS10-BB LEAK DET TWO 5A RELAYS REM 10FT SENSORIn Stock252.41126.21
BA/LDT4-RS25-BB LEAK DET TWO 5A RELAYS REM 25FT SENSORIn Stock272.99136.50
BA/LDT4-RS5-BB LEAK DET TWO 5A RELAYS REM 5FT SENSORINFO245.91122.96
BA/LTD2-RR25-BB-LTF LEAK DET TWO 0.5A RELAYS REM 25FT PLEN LT FITINFO778.20389.10
BA/LTD4-PS-BB-LTF LEAK DET TWO 5A RELAYS INTEGRAL SENSOR LT FITTINGIn Stock251.77125.89

Accessories

No accessories found
Features
  • Detection within 5 seconds with local LED indication
  • One piece, rope, or remote sensor designs
  • Adjustable detection level
  • NEMA 4 enclosure
Specifications

Materials Of Construction:Sensor: Stainless Steel

Bapi-Box: Polycarbonate:

Enclosure Rating:Remote Sensor: Submersible, with FEP plenum-rated, waterproof cable

Detector: BAPI-Box, NEMA 4:

Mounting:Lays in the pan with industrial adhesive tape or attached to the pan edge with screws

Wiring:Flex connector or liquid tight fitting; Relays: up to 6 wires for alarm contacts; Transmitter: 2 wires for power

Indicator:1 green power LED; 1 red alarm LED

Sensor:Attached SS probe w/ adjustable depth screw from 0.063″ to 0.84″

Latching and Supervised Relay Options:

Latching:Relay stays in alarm until manually reset or power in cycled

Non-Latching:Relay automatically resets after water has dried up (default)

Unsupervised:Relay energizes on water detection

Supervised:Relay de-energizes on water detection (default); Note: relay de-energizes on loss of power

Ambient Temperature:

Remote Sensor:-40° to 185℉ (-40° to 85℃)

Rope Sensor:32° to 167℉ (0° to 75℃)

Detector (BB):-40° to 185℉ (-40° to 85℃)

Ambient Humidity:

Remote Sensor:0% to 100%, condensing

Rope Sensor:0% to 95%, non-condensing

Detector (BB):0% to 95%, non-condensing

Power:18-30 VAC ~4 VA

Reset:If latching, local push button or power interrupt

Terminations:Terminal strip, 12-24 AWG

Approvals:RoHS, UL94V-0 , UV-rated in Enclosure

Weight:0.5 lb (0.2 kg)

Certifications


Download Additional Data

document   BAPI LDT Install
document   BAPI Water Leak Detector Data Sheet