Hazardous Locations

MTL5000, MTL7000, MTL7700 Series



Product Bar End
Product Bar End

MTL5000, MTL7000, MTL7700 Series

Eaton Intrinsic Safety Barriers MTL5000, MTL7000, MTL7700 Series

Eaton Intrinsic Safety Barriers

 

The MTL7000, MTL7700 and MTL5000 Series of ultra-slim intrinsic safety barriers is the worldwide standard in protection and accuracy for intrinsically safe sensing and controlling devices in hazardous locations. Each intrinsically safe barrier limits the amount of electrical energy that can be transmitted into the hazardous area to a level below the ignition energy of even the worst-case explosive mixture of fuel and air. The safety barrier protection remains intact even in the event of two simultaneous faults, thus providing the highest possible safety rating for this type of system. All MTL7000, MTL7700 and MTL5000 Series barriers are FM approved for use in intrinsically safe systems under the entity concept and can thus be applied with the widest possible array of intrinsically safe devices. Designed for ease of installation, these barriers provide a positive intrinsic safety ground through the DIN rail. These safety barriers are proven performers in building automation systems, BAS, and HVAC applications. Isolating spacers are available for applications in which the intrinsic safety ground must be separate from the mounting panel's earth ground (ANSI / ISA RP-12.6 specifies grounding requirements).


Products
Filter:

(Wholesale customers, log in for your special pricing)

QtyModelDescriptionIn StockList PriceInternet Price
BRI7000 IS BARRIER IDENTIFIERINFO46.0823.04
ERB57O EARTH RAIL MNT BRCKTINFO244.71122.35
ERL7 EARTH RAILINFO293.65146.82
ETL7000 IS DIN RAIL GROUNDING TERMIn Stock115.6757.84
ETM7 EARTH TERMINALINFO660.70330.35
IMB57 TAGGING STRIP SUPPORTINFO152.9476.47
ISP7000 IS INSULATING DIN SPACERIn Stock150.0975.04
MTL5511 IS BARRIER FOR DRY CONTACTSINFO1,089.95544.97
MTL7706+ IS BARRIER DIGITAL 4-20 MA OUTPUTIn Stock1,146.95573.48
MTL7707+ IS BARRIER DIGITAL OUTPUT/4-20 MA INPUTINFO956.59478.29
MTL7728+ IS BARRIER DIGITAL OUTPUT/4-20 MA INPUTINFO538.36269.18
MTL7755AC IS BARRIER 3 WIRE RTDINFO734.14367.07
MTL7760AC PASSIVE BARRIER MV THERMOCOUPLESINFO623.03311.51
MTL7765AC IS BARRIER 3 WIRE RTDINFO756.36378.18
MTL7767+ IS BARRIER 12 VDC SIGNALSINFO756.37378.18
MTL7787+ IS BARRIER DIGITAL OUTPUT/4-20 MA INPUTIn Stock499.38249.69
TAG57 TAGGING STRIPINFO354.82177.41
TGL7700 SPACE LABELSINFO177.4188.71

Accessories

No accessories found
Features
  • FM entity approval Class I, II, and III, Division 1, Groups A, B, C, D, E, F, G
  • BASEEFA approval EEx [ia], IIC
  • DIN rail mounting with integral intrinsic safety ground
  • Compact size
Specifications

Supply Current:45 mA typical @ 20 mAl with 24 VDC supply; 60 mA maximum @ 20 mA with a 20 VCD supply

Supply Voltage:20-35 VDC

Accuracy:2

Maximum Safe Area Voltage:250 VAC/VDC

Safe Area Load:500Ω maximum

Transmitter:16 VDC minimum @ 20 mA with 250Ω load; 11 VDC @ 20 mA with 500Ω load

Certifications