Enhanced View
Site Search
Price Check
 
Quick Order
Copy & Paste
Type It In
Enter one item per line:
Qty[TAB or COMMA]Item #

Kele Catalog Order
Network and Wireless
Network and Wireless

Product Bar End
Product Bar End
BA/EZ-COM, BA/EZ-ROM, BA/EZ-RYOM, BA/EZ-VOM

BAPI Wireless System Output Modules

The BAPI BA/ROM, VOM, COM, and RYOM Wireless System Output Modules are specifically designed to connect to any BA/RCV receiver and communicate over an RS485 communication trunk to generate standard output signals for any BAS system. A total of 127 modules may be interspersed on the RS485 trunk. Each will output a signal representative of its assigned remotely located wireless transmitter. Each module may be powered from the receiver power bus, or individually, based on overall system power requirements. The BAPI BA/ROM Thermistor Simulation Output Module converts a wireless transmitter temperature signal according to a standard thermistor curve. The two standard curves are 10 KΩ Type 3 and a 10 KΩ Type 2, with a resistance temperature response of 35° to 120°F (1° to 50°C). The BAPI BA/VOM Voltage Output Module converts a wireless transmitter temperature signal to a standard voltage signal. The two standard voltage outputs are 0-5 VDC and 0-10 VDC, with voltage temperature responses based on individual models. The BAPI BA/COM Current Output Module converts a wireless transmitter temperature signal to a standard 4-20 mA current signal. The 4-20 mA current is typical of a loop powered (9-36 VDC) device with current temperature responses based on individual models. The BAPI BA/RYOM Digital Output Module converts the pushbutton on a wireless room temperature transmitter to a solid-state relay closure for AC or DC voltages (5 second momentary actuation). NO or NC solid-state contacts are available, based on individual models. The BAPI BA/RYOL Digital Output Module converts the BA/WDI digital input tranmitter signal to a latching relay output. NO or NC contacts are available, based on individual models. The BAPI BA/SOM Setpoint Output Module converts the setpoint data from a wireless receiver to a resistance or voltage output.


arrow
Features
  • Provide BAS point wiring
  • 127 modules per system include:
  • Thermistor simulation for temperature
  • 0-10 VDC or 0-5 VDC signals
  • 4-20 mA signals
  • Solid-state contacts
  • FCC license pre-approved
  • Built-in error detection
  • Built-in fail-safe positions
  • Snap-track mounting
arrow
Specifications

Supply Voltage:

 :COM Externally (loop) powered 9-36 VDC, 20 mA

 :ROM, VOM 9-30 VDC at 3 mA, or 17 to 30 VAC at 0.1 VA

 :RYOM/RYOL 9-30 VDC at 15 mA, or 17 to 30 VAC at 0.5 VA

 :SOM See SOM data sheet located under ″Related Documents″ at www.Kele.com

Analog Output:

 :COM 4-20 mA, 9-36 VDC, loop powered Impedance 750Ω at 24 VDC

 :ROM-102 10 kΩ type 2 thermistor curve, 5 VDC excitation maximum

 :ROM-103 10 kΩ type 3 thermistor curve, 5 VDC excitation maximum

 :SOM-10 0 to 10 VDC, 10 kΩ maximum

 :SOM-60 0 to 10 kΩ, linear

 :VOM-10 0-10 VDC, 10 kΩ maximum

Digital Outputs:

 :Solid state dual FETs, NO or NC 40 VAC/VDC, 150 mA maximum 1μA leakage in off state 15Ω on-state resistance

Connections:Terminal strip (inter-lockable)

Update Interval:10 seconds

Operating Temperature:32° to 140°F (0° to 60°C)

Operating Humidity:5% to 95% RH (non-condensing)

Materials Of Construction:ABS Plastic, UL94V-0

Dimensions:2.75"H x 2.34"W x 1.2"D (7.0 x 5.9 x 3.0 cm)

Weight:0.3 lb (0.14 kg)

RoHS Statement:Yes

Warranty:1 year

arrow
Certifications


Step 1 Enter a quantity to select a product or products
Step 2 When done selecting, press Add To Cart. You may save as a Project from the Cart.
arrow
Products

(Wholesale customers, log in for your special pricing.)

QtyModelDescriptionIn StockList PriceInternet Price
BA/COM-C-EZ 4-20 MA O/P MOD,50 TO 90 F,DIN INFO137.78110.22
BA/COM-D-EZ 4-20 MA O/P MOD,55 TO 85 F,DIN INFO137.78110.22
BA/COM-E-EZ 4-20 MA O/P MOD,60 TO 80 F,DIN INFO137.78110.22
BA/COM-F-EZ 4-20 MA O/P MOD,65 TO 80 F,DIN INFO137.78110.22
BA/COM-H-EZ 4-20 MA O/P MOD,-20 TO 120 F,DIN INFO137.78110.22
BA/COM-KK-EZ 4-20 MA O/P MOD,32 TO 185 F,DIN INFO137.78110.22
BA/COM-M-EZ 4-20 MA O/P MOD,0-100% RH,DIN In Stock137.78110.22
BA/COM-MM-EZ 4-20 MA O/P MOD,-40 TO 140 F,DIN INFO137.78110.22
BA/COM-N-EZ 4-20 MA O/P MOD,35-70% RH,DIN INFO137.78110.22
BA/RYOM-NC-EZ RELAY O/P MOD,NC,MOMENTARY,DIN INFO137.78110.22
BA/RYOM-NO-EZ RELAY O/P MOD,NO,MOMENTARY,DIN INFO137.78110.22
BA/SOM-00-EZ S/P O/P MOD,0-5V O/P,DIN INFO137.78110.22
BA/SOM-01-EZ S/P O/P MOD,1-5V O/P,DIN INFO137.78110.22
BA/SOM-02-EZ S/P O/P MOD,3.7-.85V O/P,DIN INFO137.78110.22
BA/SOM-03-EZ S/P O/P MOD,5-0V O/P,DIN INFO137.78110.22
BA/SOM-04-EZ S/P O/P MOD,4.2-1.2V O/P,DIN INFO137.78110.22
BA/SOM-05-EZ S/P O/P MOD,2.75-3.34V O/P,DIN INFO137.78110.22
BA/SOM-06-EZ S/P O/P MOD,2.88-3.17V O/P,DIN INFO137.78110.22
BA/SOM-10-EZ S/P O/P MOD,0-10V O/P,DIN INFO137.78110.22
BA/SOM-11-EZ S/P O/P MOD,2-10V O/P,DIN INFO137.78110.22
BA/SOM-16-EZ S/P O/P MOD,4-20MA O/P,DIN INFO137.78110.22
BA/SOM-50-EZ S/P O/P MOD,0 TO 5K OHM O/P,DIN INFO137.78110.22
BA/SOM-51-EZ S/P O/P MOD,7.87K TO 2.87K OHM O/P,DIN INFO137.78110.22
BA/SOM-60-EZ S/P O/P MOD,0 TO 10K OHM O/P,DIN INFO137.78110.22
BA/SOM-61-EZ S/P O/P MOD,15K TO 5K OHM O/P,DIN INFO137.78110.22
BA/SOM-62-EZ S/P O/P MOD,9,577 TO 1,422 OHM O/P,DIN INFO137.78110.22
BA/SOM-63-EZ S/P O/P MOD,1K TO 11K OHM O/P,DIN INFO137.78110.22
BA/SOM-80-EZ S/P O/P MOD,0 TO 20K OHM O/P,DIN INFO137.78110.22
BA/SOM-81-EZ S/P O/P MOD,4.75K TO 24.75K OHM O/P,DIN INFO137.78110.22
BA/SOM-82-EZ S/P O/P MOD,6.19K TO 26.19K OHM O/P,DIN INFO137.78110.22
BA/SOM-83-EZ S/P O/P MOD,7.87K TO 27.87K OHM O/P,DIN INFO137.78110.22
BA/SOM-84-EZ S/P O/P MOD,10K TO 30K OHM O/P,DIN INFO137.78110.22
BA/SOM-85-EZ S/P O/P MOD,24.75K TO 4.75K OHM O/P,DIN INFO137.78110.22
BA/VOM-05-C-EZ 0-5V O/P MOD,50 TO 90 F,DIN In Stock137.78110.22
BA/VOM-05-D-EZ 0-5V O/P MOD,55 TO 85 F,DIN INFO137.78110.22
BA/VOM-05-E-EZ 0-5V O/P MOD,60 TO 80 F DIN INFO137.78110.22
BA/VOM-05-F-EZ 0-5V O/P MOD,65 TO 80 F INFO133.33106.66
BA/VOM-05-H-EZ 0-5V O/P MOD,-20 TO 120 F,DIN INFO137.78110.22
BA/VOM-05-KK-EZ 0-5V O/P MOD,32 TO 185 F,DIN INFO137.78110.22
BA/VOM-05-M-EZ 0-5V O/P MOD,0-100% RH,DIN INFO137.78110.22
BA/VOM-05-MM-EZ 0-5V O/P MOD,-40 TO 140 F,DIN INFO137.78110.22
BA/VOM-05-N-EZ 0-5V O/P MOD,35-70% RH,DIN INFO137.78110.22
BA/VOM-10-C-EZ 0-10V O/P MOD,50 TO 90 F,DIN INFO137.78110.22
BA/VOM-10-D-EZ 0-10V O/P MOD,55 TO 85 F,DIN INFO137.78110.22
BA/VOM-10-E-EZ 0-10V O/P MOD,60 TO 80 F,DIN INFO137.78110.22
BA/VOM-10-F-EZ 0-10V O/P MOD,65 TO 80 F,DIN INFO137.78110.22
BA/VOM-10-H-EZ 0-10V O/P MOD,-20 TO 120 F,DIN INFO137.78110.22
BA/VOM-10-KK-EZ 0-10V O/P MOD,32 TO 185 F,DIN INFO137.78110.22
BA/VOM-10-M-EZ 0-10V O/P MOD,0-100% RH,DIN In Stock137.78110.22
BA/VOM-10-MM-EZ 0-10V O/P MOD,-40 TO 140 F,DIN INFO137.78110.22
BA/VOM-10-N-EZ 0-10V O/P MOD,35-70% RH,DIN INFO137.78110.22
BA/FV418K FIELD VERIFIER KIT,418 MHZ INFO1,602.731,282.18
BA/FV900K FIELD VERIFIER KIT,900 MHZ INFO2,110.091,688.07
BA/LI3620 AA LITHIUM 36V BATTERY In Stock26.6621.33
BA/RYOL-NO-EZ RELAY OUTPUT, LATCHING, DEFAULT TO NORMALLY OPN INFO139.30111.44
BA/RYOM-NC-DIN RELAY OP MOD,NC,MOMENTARY,DIN INFO137.78110.22
BA/RYOM-NO-DIN RELAY OP MOD,NO,MOMENTARY,DIN INFO137.78110.22
BA/VF-KIT FIELD VERIFIER KIT,418 & 900 MHZ INFO3,566.502,853.20
BA/WT-RPFEP-15 REM PRB W/ FEP JACKETED CABLE,15FT LDS INFO320.89256.71
BA/WT-RPFEP-20 REM PRB W/ FEP JACKETED CABLE,20FT LDS INFO322.67258.14
BA/WT-RPFEP-25 REM PRB W/ FEP JACKETED CABLE,25FT LDS INFO324.44259.55
BA/WT-TB-M304-2-BB WIRELESS THOMOBUFFER,SS,2IN PROBE INFO531.99425.59
BA/WT-TB-M304-4-BB WIRELESS THOMOBUFFER,SS,4IN PROBE INFO472.89378.31
BA/WT-TB-MAL-2-BB WIRELESS THOMOBUFFER,ALUM,2IN PROBE INFO419.56335.65
BA/WT-TB-MAL-4-BB WIRELESS THOMOBUFFER,ALUM,4IN PROBE INFO419.56335.65
VC350-12 POWER SUPPLY 24VAC TO 12 VDC @350MA In Stock25.9320.74
arrow
Accessories
No accessories found
KeleBA/EZ-COM, BA/EZ-ROM, BA/EZ-RYOM, BA/EZ-VOM
Overall rating 
4 / 5
4 / 5
Open Ratings Snapshot
Rating breakdown 1 review
5 Stars
0
4 Stars
1
3 Stars
0
2 Stars
0
1 Star
0
Ease of Installation 
5 / 5
5 / 5
Quality / Performance 
5 / 5
5 / 5
Technology 
5 / 5
5 / 5
Value 
3 / 5
3 / 5
1 out of 1(100%)customers recommend this product.
1
1 The BAPI BA/ROM, VOM, COM, and RYOM Wireless System Output Modules are specifically designed to connect to any BA/RCV receiver and communicate over an RS485 communication trunk to generate standard output signals for any BAS system. A total of 127 modules may be interspersed on the RS485 trunk. Each will output a signal representative of its assigned remotely located wireless transmitter. Each module may be powered from the receiver power bus, or individually, based on overall system power requirements. The BAPI BA/ROM Thermistor Simulation Output Module converts a wireless transmitter temperature signal according to a standard thermistor curve. The two standard curves are 10 KΩ Type 3 and a 10 KΩ Type 2, with a resistance temperature response of 35° to 120°F (1° to 50°C). The BAPI BA/VOM Voltage Output Module converts a wireless transmitter temperature signal to a standard voltage signal. The two standard voltage outputs are 0-5 VDC and 0-10 VDC, with voltage temperature responses based on individual models. The BAPI BA/COM Current Output Module converts a wireless transmitter temperature signal to a standard 4-20 mA current signal. The 4-20 mA current is typical of a loop powered (9-36 VDC) device with current temperature responses based on individual models. The BAPI BA/RYOM Digital Output Module converts the pushbutton on a wireless room temperature transmitter to a solid-state relay closure for AC or DC voltages (5 second momentary actuation). NO or NC solid-state contacts are available, based on individual models. The BAPI BA/RYOL Digital Output Module converts the BA/WDI digital input tranmitter signal to a latching relay output. NO or NC contacts are available, based on individual models. The BAPI BA/SOM Setpoint Output Module converts the setpoint data from a wireless receiver to a resistance or voltage output.
Overall rating 
4 / 5
4 / 5
Open Ratings Snapshot
Rating breakdown 1 review
5 Stars
0
4 Stars
1
3 Stars
0
2 Stars
0
1 Star
0
Ease of Installation 
5 / 5
5 / 5
Quality / Performance 
5 / 5
5 / 5
Technology 
5 / 5
5 / 5
Value 
3 / 5
3 / 5
1 out of 1(100%)customers recommend this product.
Product ReviewsWrite a review
Overall rating 
4 / 5
4 / 5
Great performance, high price
PostedJuly 5, 2011
Customer avatar
vpelleri
 
Please wait while more information about vpelleri is loaded.
Additional information about vpelleri could not be loaded.
from Colorado
Years of Experience:11+
Job Function:Engineering / Design
Ease of Installation 
5 / 5
5 / 5
Quality / Performance 
5 / 5
5 / 5
Technology 
5 / 5
5 / 5
Value 
3 / 5
3 / 5
We have used these in a couple of installations where wiring was either impossible or would take a great deal of time to install. Our first installation used the thermistor module and we had a failure right away. Using the 0-10Vdc module we've had no failures. System is stable and easy to install and set up. It is a bit pricey, but the money and headaches saved on installation somewhat makes up for it. BAPI will even send out a radio test kit to see if it will work for you.
My Favorite Feature Works even through concrete
Pros: works!
Cons: pricey
Yes, I recommend this product.
0points
0of 0voted this as helpful.
Was this helpful?helpful0unhelpful0
Thank you! You have successfully submitted a comment for this review.
Filtering is in progress. Please wait until it completes.
1-1 of 1