POW-R-GATE
PowerGate-2009

Mitsubishi HVAC Bypass System - NEMA1 Current Rated VFD

Pow R Gate Bypass Controller System is intended to support the needs of the HVAC industry, but is also useful for a wide range of pump and fan control applications in other industries.



arrow
Features

• RS485 and ModbusRTU as standard

• MetasysN2, LONWORKS, BACnetIP or MSTP/RS485, SiemensFLN, Ethernet/IPTM, ModbusTCP/IP

Estop string with provisions for N.C. contacts

• Damper end switch and damper output actuator

• Design/build options available for your needs

• All field terminations brought out to terminal blocks

• Carrier frequency up to 14.5 KHz

• Speed Match-Catch spinning load (FWD or REV)

• 3 Customizable critical skip frequency bands

• SoftPWM control (low noise emissions)

• EMI/RFI filter builtin as standard

• Optimized Excitation Control-Motor tuning

• Builtin PID control with presoak mode as standard

• Selectable electronic overload protection

• Software setup for programming and monitoring

• 010VDC or 420mA inputs for speed reference

• 15 Preset speeds

• HELP functionality with troubleshooting hints

• Last 8 alarms stored

• DC Link reactor standard

• All drives are tested under motor load

arrow
Specifications

Input ratings:

  Voltage:3phase, 200240V; 380480V 15% / +10% 

  Frequency:50/60 Hz; +/5%

Output ratings:0 Volts to Max Voltage, Frequency 0400Hz

Overload rating:

  • 120% for 60s (150% for 3s):

  • 120% for 60s (150% for 3s):

Environment:95% RH (Noncondensing) 14F to 104F Ambient (10C to + 40C)

I/O control:

  • 4 Programmable analog inputs:

  • 7 Programmable digital inputs:

  • 6 Programmable open collector outputs:

  • 2 Programmable analog output:

  • 2 System fault output:

Options:

  • Circuit breaker or fused disconnect 3% or 5% input:

  • line impedance:

  • Automatic bypass (following VFD fault):

  • Output line reactor:

  • RFI filters / harmonic filters:

  • Third Party Devices:Well bulb sensors, transducer, pressure sensors

 Protection::

  • Overcurrent (3 Modes):

  • Overload (2 Modes):

  • Undervoltage:

  • Groundfault:

  • Motor stall:

  • Retry timeout:

  • Microprocessor fault (2 Modes):

  • Overvoltage (3 modes):

  • Instant power loss:

  • Overheat:

  • Motor overheat (I2t):

  • Option alarm:

  • CPU fault (3 Modes):

  • Output phase loss:

  • Power supply fault:

arrow
Certifications
UL

CUL-US