POW-R-GATE
 
Product Information
 
 
PowerGate-2009
Mitsubishi HVAC Bypass System - NEMA1 Current Rated VFD
arrow
Description

Pow R Gate Bypass Controller System is intended to support the needs of the HVAC industry, but is also useful for a wide range of pump and fan control applications in other industries.

arrow
Features

• RS485 and ModbusRTU as standard

• MetasysN2, LONWORKS, BACnetIP or MSTP/RS485, SiemensFLN, Ethernet/IPTM, ModbusTCP/IP

Estop string with provisions for N.C. contacts

• Damper end switch and damper output actuator

• Design/build options available for your needs

• All field terminations brought out to terminal blocks

• Carrier frequency up to 14.5 KHz

• Speed Match-Catch spinning load (FWD or REV)

• 3 Customizable critical skip frequency bands

• SoftPWM control (low noise emissions)

• EMI/RFI filter builtin as standard

• Optimized Excitation Control-Motor tuning

• Builtin PID control with presoak mode as standard

• Selectable electronic overload protection

• Software setup for programming and monitoring

• 010VDC or 420mA inputs for speed reference

• 15 Preset speeds

• HELP functionality with troubleshooting hints

• Last 8 alarms stored

• DC Link reactor standard

• All drives are tested under motor load

arrow
Specifications
Input ratings
  Voltage:3phase, 200240V; 380480V 15% / +10% 
  Frequency:50/60 Hz; +/5%
Output ratings:0 Volts to Max Voltage, Frequency 0400Hz
Overload rating
  • 120% for 60s (150% for 3s)
  • 120% for 60s (150% for 3s)
Environment:95% RH (Noncondensing) 14F to 104F Ambient (10C to + 40C)
I/O control
  • 4 Programmable analog inputs
  • 7 Programmable digital inputs
  • 6 Programmable open collector outputs
  • 2 Programmable analog output
  • 2 System fault output
Options
  • Circuit breaker or fused disconnect 3% or 5% input
  • line impedance
  • Automatic bypass (following VFD fault)
  • Output line reactor
  • RFI filters / harmonic filters
  • Third Party Devices:Well bulb sensors, transducer, pressure sensors
 Protection:
  • Overcurrent (3 Modes)
  • Overload (2 Modes)
  • Undervoltage
  • Groundfault
  • Motor stall
  • Retry timeout
  • Microprocessor fault (2 Modes)
  • Overvoltage (3 modes)
  • Instant power loss
  • Overheat
  • Motor overheat (I2t)
  • Option alarm
  • CPU fault (3 Modes)
  • Output phase loss
  • Power supply fault
arrow
Certifications
UL
CUL-US