Supply Voltage:120/240 VAC 50/60 Hz
Analog Output:4-20 mA loop powered, 18-36 VDC, RL=500Ω maximum
Relay Type: 2-SPST (leak detection)
:2-SPST (cable break detection)
Relay Outputs:1A @ 24 VDC, 0.5A resisitive @ 120 VAC
Accuracy: ±2 ft (0.6m) plus ±0.5% of the cable length
Repeatability: ±2 ft (0.6m) ±0.25% of the cable length
Communication Ports:
Ethernet:10/100 BASE-T, 500 VAC RMA isolation
RS-232:9600 baud, no parity, 9 data bits, 1 stop bit
RS-485:1200, 2400, 9600 or 19200 baud selectable, no parity, 8 data bits, 1 stop bit
Protocol:
Terminal Emulation:
(RS-232):VT100 compatible
Modbus (RS-485):Slave, RTU mode; supports function codes 03, 04, 06, and 16
Display: Graphic, 160 x 160 pixel resolution backlit LCD with contrast adjustment
LED Indication:1 bi-color power/status (green=power on, red=alarm)
Response Time:Adjustable from 20-3600 seconds
Alarm: Audible: 85 dBa @ 2' (0.6m); resound 0-999 minutes
Altitude Limits:15,000 ft (4,572m) maximum
Logging Samples:Event log: Last 512 events
Trend log: Cable current everyday, for last 288 days:
Security Login:Terminal emulation access: No login required
Display access: 1 administrator (password for configuration, not to view status):
Operating Humidity:5% to 95% non-condensing
Operating Temperature:32° to 122°F (0° to 50°C)
Mounting: Wall mount
Cable Length:5000 ft (1522m) maximum
Cable Type: Water detection cable
Dimensions: 12.6"H x 10.0"W x 3.3"D (32.0 x 25.4 x 82.5 cm)
Approvals: CE, ETL Listed, RoHS compliant
Weight: 10 lb (4.53 kg) without cable
Warranty: 1 year