The Telaire T8000 Series Ventostat CO2/RH/Temperature Transmitter is the next generation CO2 sensor from GE Sensing. Each GE Ventostat comes with a passive 10kΩ Type II thermistor and has simultaneously active voltage and current outputs for CO2 measurement. The T8100 and T8300 features reliable automatic calibration using patented Telaire ABC logic that will ensure accurate and stable calibration for the lifetime of the sensor. The T8200 offers an accurate solution for hospitals and other full time operational 24 hours a day facilities. Both the T8100 sensor and the T8200 sensor are available with optional and selectable analog humidity and temperature outputs. The T8300 offers all of the accuracy of the T8100 but utilizes a pitot tube kit for measuring duct levels of CO2. Telaire CO2 sensors are indispensable for Building Automation Systems, BAS, and HVAC applications.


Products
Filter:

(Wholesale customers, log in for your special pricing)

QtyModelDescriptionIn StockList PriceInternet Price
T1505 SPLASH RESISTANT ENCLOSURE INFO360.96288.77
T1508 DUCT ASPIRATION BOX In Stock400.02320.02
T1551 OUTDOOR AIR ENCL FOR OLD 8002 MODELS (HEATED) In Stock515.02412.02
T1552 OUTDOOR AIR ENCL FOR 8100, 8200 & 8300 (HEATED) In Stock524.91419.93
T2075NG CALIBRATION KIT W/O GAS INFO1,031.55825.24
T2090 T8100 CALIBRATION SOFTWARE INFO375.39300.31
T8042 DUCT CO2 XMTR In Stock495.65396.52
T8100 WALL-MNT CO2 SNSR, NO DISPLAY, WHITE - NO RELAY In Stock456.57365.25
T8100-ASP WALL MNT CO2 SNSR, W/T1508 INFO643.67514.93
T8100-B WALL-MNT CO2 SNSR, NO DISPLAY BLACK - NO RELAY INFO501.50401.20
T8100-D WALL-MNT CO2 SNSR, LCD DISPLAY, WHITE - NO RELAY In Stock505.18404.14
T8100-D-5P-R WALL-MNT CO2 SNSR LCD DISPLAY WHITE RELAY TEMP INFO845.45676.36
T8100-D-ASP WALL MNT CO2 SNSR, W/LCD & T1508 INFO697.18557.74
T8100-D-R WALL-MNT CO2 SNSR LCD DISPLAY WHITE RELAY INFO582.69466.15
T8100-DB WALL-MNT CO2 SNSR, LCD DISPLAY, BLACK - NO RELAY In Stock552.48441.98
T8100-H CO2/RH/TEMP XMTR - NO RELAY In Stock623.68498.95
T8100-HD CO2/RH/TEMP XMTR W/DISPLAY - NO RELAY INFO702.27561.81
T8100-HDB WALL-MNT CO2, RH% ACTIVE TEMP LCD DISP BLK-NO RLY INFO725.12580.09
T8200 WALL-MNT CO2 SNSR, WHT FULL TIME OCC APP-NO RLY INFO601.77481.42
T8200-B WALL CO2 SNSR, BLACK FULL TIME OCC APP-NO RLY INFO624.79499.83
T8200-D WALL CO2, W/LCD, WHT FULL TIME OCC APP-NO RELAY In Stock652.76522.21
T8200-DB WALL CO2, W/LCD, BLK FULL TIME OCC APP-NO RELAY INFO675.77540.62
T8300-B DUCT MNT, PITOT TUBE KIT CO2 SNSR BLACK-NO RELAY INFO633.82507.06
T8300-DB DUCT MNT PITOT TUBE KIT CO2 SNSR W/LCD BLK-NO RLY In Stock646.17516.93
T8700-D  DUCT MOUNT CO2 SENSOR INFO381.58305.26

Accessories

No accessories found
Features
  • Simultaneous voltage and current outputs for CO2
  • Maintenance free lifetime self-calibration
  • Passive temperature output
  • Non-dispersive infrared sensor
  • Ideal for 24 hours per day facilities (T8200)
  • Optional display available
  • Optional active temperature and humidity outputs
Specifications

Supply Voltage:18-30 VAC @ 0.7 VA, 50/60 Hz or 18-42 VDC @ 29 mA

Signal Output:0-5V, 0-10V, or 4-20 mA (500 ohms ) selectable for CO2, humidity, or temperature (simultaneous current or voltage output for CO2)

Accuracy:

T8100/T8300: 400-1250 ppm: 3% or 30 ppm, whichever is greater; 1250-2000 ppm: ±5% +30ppm,

T8200:10% or 75 ppm, whichever is greater;

Humidity:±2.5% RH (20 to 80% RH)

Temperature: ±0.8% @ 72°F (22°C)

Measurement Range:

CO2:0 to 2000 ppm

Humidity:0 to 99% RH (non condensing)

Temperature:32° to 122°F (0° to 50°C)

Sensing Technology:

CO2:Non-dispersive infrared (NDIR)

Humidity:Capacitive polymer

Temperature:Passive: 10kΩ Type II thermistor

Warm up time:(CO2) 10 minutes

Display:Scrolling LCD

Response Time:5 seconds

Operating Humidity:0% to 95% RH

Operating Temperature:32° to 122°F (0° to 50°C)

Approvals:RoHS, CE

Weight:1.0 lb (0.45 kg)

Warranty:1 year (lifetime on calibration)