Supply Voltage:17-27 VAC, 50/60 Hz, 0.35A; 24-38 VDC
Signal Output:4-20 mA
Alarm Relay Output:DPDT pilot duty, 150 VA max inductive, 5A @ 30 VDC, 250 VAC
Alarm Auditory Levels:85 dBA @ 10 ft (3m)
Measurement Range:
CO:0-250 ppm
O2:0% to 25%
H2S:0-50 ppm
NO2:0-10 ppm
CH4, C3H8, H2:0% to 100% LEL
Sensing Technology:
CO, O2, H2S, NO2:Electrochemical
CH4, C3H8, H2:Catalytic combustion
Calibration Interval:6 months
Life Expectancy:
CO:6 years
All Others: 2 years
Visual Indication:Green LED: power Amber LED 1: Alarm/fault Amber LED 2: Alarm/fault
Display: 8 character, two-line LCD
Display Resolution:
CO:1 ppm
O2:0.2%
H2S, NO2:0.2 ppm
CH4, C3H8, H2:0.5%
Operating Temperature:
CO:-4° to 122°F (-20° to 50°C)
All Others:-40° to 122°F (-40° to 50°C)
:
Enclosure: Polycarbonate
Dimensions: 8.1''H x 5.9''W x 2.7''D (20.6 x 14.9 x 6.7 cm)
Approvals: UL61010, CSA C22.2
Weight: 0.86 lb (0.35 kg)
Warranty: 1 year