Flow

DTFXL Series



Product Bar End
Product Bar End

DTFXL Series

Dynasonics Ultrasonic Flowmeters DTFXL Series

Dynasonics Ultrasonic Flowmeters

 

The DTFXL Series ultrasonic flowmeter is a popular choice for Building Automation Systems, BAS, and HVAC applications. It measures water flow in a wide variety of pipe sizes and pipe materials, using clamp-on sensors that attach to the outside of the pipe. This non-invasive, non-contact flow meter provides instantaneous flow rate and accumulated flow and provides a 4-20 mA output as well as pulse outputs. The DTFXL Series flow meter is easy to install, has a large bidirectional flow range, and comes with or without a display. Configuration, monitoring, and calibration of the DTXFL is accomplished with an easy-to-use software package via a cable connection from a PC to the flow meter. For systems using water/glycol solutions, the higher-powered DB Series ultrasonic flow meter may perform better.


Products
Filter:

(Wholesale customers, log in for your special pricing)

QtyModelDescriptionIn StockList PriceInternet Price
D002-2007-001 MOUNTING STRAP,36IN, NEEDED FOR REMOTE XDUCER In Stock26.2320.98
D002-2011-001 5.3 OZ LUBRICANT, ACOUSTIC In Stock54.8543.88
D005-0803-104 ULTRALINK PC SOFTWARE In Stock94.9275.94
D005-2116-004 9 PIN TO USB CONNECTOR INFO347.20277.76
D010-0204-001 PC CABLE In Stock272.39217.91
D010-2102-010 MOUNTING TRACK FOR REMOTE XDUCERS FOR 2-10IN PIPE In Stock488.57390.86
D010-2102-016 MOUNTING TRK (DTTN/H XDUCERS) FOR 2 TO 16IN PIPES INFO751.98601.58
DTFXL1-AN1-NN CLAMP-ON,1/2IN PIPE,NO DISPLAY,4-20MA AND PULSE INFO2,720.612,176.49
DTFXL1-BN1-NN CLAMP-ON,3/4IN PIPE,NO DISPLAY,4-20MA AND PULSE INFO2,720.612,176.49
DTFXL1-CN1-NN CLAMP-ON,1IN PIPE,NO DISPLAY,4-20MA AND PULSE INFO2,782.172,225.74
DTFXL1-DN1-NN CLAMP-ON,1 1/4IN PIPE,NO DISPLAY,4-20MA AND PULSE INFO2,805.852,244.68
DTFXL1-EN1-NN CLAMP-ON,1 1/2IN PIPE,NO DISPLAY,4-20MA AND PULSE INFO2,805.852,244.68
DTFXL1-FN1-NN CLAMP-ON,2IN PIPE,NO DISPLAY,4-20MA AND PULSE INFO2,902.932,322.34
DTFXL1-IN1-NN TRANSMITTER WITH TRANSDUCER 1 IN COPPER INFO3,193.002,554.40
DTFXL1-KN1-NN TRANSMITTER WITH TRANSDUCER 1 1/2IN COPPER INFO3,216.692,573.35
DTFXL1-XN1-NN REMOTE MOUNT, NO DISPLAY,4-20MA AND PULSE In Stock2,306.241,844.99
DTFXL1-XN1-NN-C REMOTE MOUNT,NO DISPLAY,4-20 MA,PULSE In Stock2,370.031,896.02
DTFXL2-AN1-NN CLAMP-ON,1/2IN PIPE,DISPLAY,4-20MA AND PULSE INFO3,075.782,460.62
DTFXL2-AN1-NN-C CLAMP-ON,1/2IN ANSI,DISPLAY,CONFIG. BY KELE INFO3,160.042,528.03
DTFXL2-BN1-NN CLAMP-ON,3/4IN PIPE,DISPLAY,4-20MA AND PULSE INFO3,075.782,460.62
DTFXL2-BN1-NN-C CLAMP-ON,3/4IN ANSI,DISPLAY,CONFIG. BY KELE INFO3,160.042,528.03
DTFXL2-CN1-NN CLAMP-ON,1IN PIPE,DISPLAY,4-20MA AND PULSE INFO3,137.342,509.87
DTFXL2-CN1-NN-C CLAMP-ON,1IN ANSI,DISPLAY,CONFIG. BY KELE INFO3,222.872,578.30
DTFXL2-DN1-NN CLAMP-ON,1 1/4IN PIPE,DISPLAY,4-20MA AND PULSE INFO3,161.022,528.82
DTFXL2-DN1-NN-C CLAMP-ON,1 1/4IN ANSI,DISPLAY,CONFIG. BY KELE INFO3,248.622,598.90
DTFXL2-EN1-NN CLAMP-ON,1 1/2IN PIPE,DISPLAY,4-20MA AND PULSE INFO3,161.022,528.82
DTFXL2-EN1-NN-C CLAMP-ON,1 1/2IN ANSI,DISPLAY,CONFIG. BY KELE INFO3,248.622,598.90
DTFXL2-FN1-NN CLAMP-ON,2IN PIPE,DISPLAY,4-20MA AND PULSE INFO3,258.102,606.48
DTFXL2-FN1-NN-C CLAMP-ON,2IN ANSI,DISPLAY,CONFIG. BY KELE INFO3,348.532,678.82
DTFXL2-HN1-NN 3/4IN, 4-20MA AND TTL PULSE FLOW METER INFO3,075.782,460.62
DTFXL2-LN1-NN TRANSMITTER WITH TRANSDUCER 2 IN COPPER INFO3,313.512,650.81
DTFXL2-XN1-NN REMOTE MOUNT, DISPLAY,4-20MA AND PULSE In Stock2,661.422,129.14
DTFXL2-XN1-NN-C REMOTE MOUNT,DISPLAY,4-20 MA,PULSE In Stock2,733.622,186.90
DTTN-020-N000-N REMOTE XDCR 2.5IN AND UP PIPE 20FT CBL 4STRAPS In Stock1,550.911,240.73
DTTN-050-N000-N REMOTE XDCR 2.5IN/UP 50FT CABLE 4 STRAP In Stock1,747.441,397.95
DTTN-100-N000-N REMOTE XDCR FOR 2.5IN AND UP PIPE,100FT CBL, 4 INFO2,003.161,602.53

Accessories

No accessories found
Features
  • Transit time technology in an economical package
  • Can handle some suspended solids and gas pockets
  • Bidirectional flow range for changeover systems
  • Multiple totalizers for forward, reverse, net
  • Models with or without display
  • Selectable standard or metric engineering units
  • Non-invasive, no system down time to install
  • 4-20 mA output plus choice of pulse outputs
  • Optional armored cable
  • High temperature transducers available
Specifications

Supply Voltage:12-28 VDC

Frequency:0-1000 Hz for Turbine output (non-ground referenced AC and 100 mV pp minimum), switch selectable; 5 VDC pp ground-referenced square wave for TTL output

Supply Current:0.25 A

Maximum Output Impedance:900Ω maximum for 4-20 mA output; source power can share common with power supply

Outputs:4-20 mA and Turbine or TTL

Conduit Opening:1/2" conduit knockout (7/8" hole, 2.2 cm)

Cable Length:Remote transducer models available with 20' (6.1m), 50' (15m), or 100' (30m) cables

Accuracy:± 1.0% of reading above 1 fps (0.3 mps) velocity, ± 0.01% of reading below 1 fps (0.3 mps)

Response Time:0.3 to 30 seconds, adjustable

Display:Two-line x eight-character LCD

Operating Temperature:-40° to 185℉ (-40° to 85℃); remote DTTS/DTTN transducers have upper limit of 250℉ (121℃) and high temperature DTTH transducers have upper limit of 400℉ (200℃)

Velocity Range:0.1 to 40 fps (feet/second), 0.03 to 12.4 mps (meters/second), bi-directional

Pipe Size Range:1/2" (1.2 cm) and up

Media Compatibility:Most clean liquids or liquids with some suspended solids or aeration, not recommended for glycol solutions, not for steam; for water/glycol systems the DE Series is recommended

Enclosure Rating:NEMA 4X as long as a liquid-tight connector is used

Approvals:ANSI/ISA 582.01; CSA C22.2 No. 213, E79-15-95

Warranty:1 year

Certifications